We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Papers
20 resultsShowing papers similar to Influence of Different Coagulants on Microplastics Removal
ClearInvestigating the Potential of Coagulants to Improve Microplastics Removal in Wastewater and Tap Water
Researchers found that adding coagulants (FeCl3 or Al2(SO4)3) to wastewater and tap water improved microplastic removal, with aluminum sulfate achieving 43% and 62% removal efficiencies respectively, though the high concentrations required suggest that combining coagulants with organic polyelectrolytes could improve practicality.
The influence of coagulation process conditions on theefficiency of microplastic removal in water treatment
Researchers investigated how coagulation process conditions — including coagulant type, pH, and microsand addition — affect the removal of polyethylene, PVC, and textile microfibers from river water, municipal wastewater, laundry effluent, and synthetic matrices. Ferric chloride and polyaluminum chloride both achieved substantial removal, with performance varying significantly by water matrix and microplastic type.
Microplastics removal from aquatic environment by coagulation: Selecting the best coagulant based on variables determined from a systematic review
This systematic review and experimental study identifies the most effective methods for removing microplastics from water using coagulation, a common water treatment technique. Researchers tested different coagulants on three types of microplastics and found that aluminum-based coagulants were most effective. These findings could help water treatment plants better remove microplastics from the water supply before it reaches our taps.
Microplastics removal from natural surface water by coagulation process
Researchers compared the effectiveness of ferrous and aluminum sulfate coagulants for removing microplastics from natural surface water, finding that both successfully removed polystyrene and polyvinyl chloride particles. Ferrous sulfate showed slightly higher removal efficiency, and the addition of coagulant aids further improved results. The study demonstrates that conventional coagulation processes already used in drinking water treatment can meaningfully reduce microplastic contamination.
Efficiency and mechanism of micro- and nano-plastic removal with polymeric Al-Fe bimetallic coagulants: Role of Fe addition
Researchers investigated polymeric Al-Fe bimetallic coagulants for removing micro- and nanoplastics from drinking water, finding that iron addition enhanced nanoplastic removal efficiency through improved charge neutralization and floc formation mechanisms.
Coagulation of Wastewater Containing Polyethylene Terephthalate (PET) Microplastics by Using Ferric Chloride, Aluminum Sulfate and Aluminum Chlorohydrate: A Comparative Study
Researchers compared ferric chloride, aluminum sulfate, and aluminum chlorohydrate coagulants for removing PET microplastics from plastic recycling facility wastewater, finding that aluminum sulfate at pH 6 achieved the highest removal rate of 90% for predominantly fragment-shaped MPs in the 251-500 micrometers size range.
Chemical Coagulation Applied for the Removal of Polyethylene and Expanded Polystyrene Microplastics
Researchers evaluated the use of aluminum sulfate-based coagulation and flocculation processes for removing polyethylene and expanded polystyrene microplastics from water. The study used factorial experimental designs to optimize treatment conditions including coagulant dosage and pH, demonstrating the potential of chemical coagulation as a microplastic removal strategy.
Microplastics and nanoplastics in water: Improving removal in wastewater treatment plants with alternative coagulants
Laboratory tests showed that conventional aluminum sulfate (alum) coagulant becomes much less effective at removing micro- and nanoplastics from water at pH above 7.8—a common condition in municipal wastewater—but switching to aluminum chlorohydrate largely restores removal efficiency. This matters because wastewater treatment plants are a critical barrier preventing microplastics from entering rivers and oceans, and many currently use alum. The study gives water utilities a practical, drop-in solution to significantly improve microplastic capture under challenging water chemistry.
Removal of Microplastics from Wastewater Treatment Plants by Coagulation
Researchers tested coagulation-based methods for removing microplastics from wastewater using polyaluminum chloride and polyferric sulfate, with and without polyacrylamide additives. The best results came from combining polyaluminum chloride with cationic polyacrylamide, which achieved 87.5% removal of polystyrene microplastics. The study suggests that cationic polyacrylamide works especially well because of electrostatic interactions with negatively charged microplastic particles.
Surface characteristics of polystyrene microplastics mainly determine their coagulation performances
Researchers evaluated polyaluminum sulfate coagulant for removing polystyrene microplastics from water, achieving 90.4% removal at optimal dosage. Surface characteristics of microplastics including density, particle size, and adsorbed substances significantly influenced coagulation efficiency.
Enhancing microplastic removal from natural water using coagulant aids
Researchers tested different chemical treatments for removing microplastic beads from natural water and found that polyaluminium chloride combined with polyacrylamide achieved over 95% removal across six common plastic types. The treatment worked on particles ranging from 10 to 1,000 micrometers, and natural organic matter in the water actually improved performance. The findings suggest that optimizing standard water treatment processes could be a practical way to reduce microplastic contamination in drinking water sources.
The removal of microplastics from water by coagulation: A comprehensive review
This review comprehensively examined coagulation as a technology for removing microplastics from drinking water and wastewater treatment plants, analyzing the mechanisms, influencing factors, and effectiveness of different coagulants for microplastic removal.
Research on Effect of Microplastics Removal through Combination of Coagulation and Sand Filtration
Researchers tested three coagulants — ferric chloride (FeCl3), polyferric sulfate (PFS), and polyaluminum chloride (PAC) — for microplastic removal from secondary wastewater effluent, finding that 40 mg/L PFS achieved the highest coagulation removal rate of 61%. A combined PFS plus sand filtration process removed 91% of microplastics, 82% of suspended solids, and 85% of total phosphorus at a treatment cost of approximately 0.0594 Yuan per tonne of wastewater.
Removal of polystyrene and polyethylene microplastics using PAC and FeCl3 coagulation: Performance and mechanism
Researchers studied how two common water treatment coagulants, PAC and iron chloride, remove polystyrene and polyethylene microplastics from water. They found that PAC was more effective than iron chloride, and that alkaline conditions improved removal rates. The study provides practical insights for drinking water treatment plants looking to reduce microplastic contamination in their supply.
Removal of microplastics from secondary wastewater treatment plant effluent by coagulation/flocculation with iron, aluminum and polyamine-based chemicals
Researchers tested iron, aluminum, and polyamine-based coagulants for removing small microplastics (<10 µm) from secondary wastewater treatment plant effluent, finding that coagulation-flocculation can remove a substantial fraction but that efficiency varies by chemical and particle size.
Coagulation performance and mechanism of different hydrolyzed aluminum species for the removal of composite pollutants of polyethylene and humic acid
Researchers examined how different forms of hydrolyzed aluminum coagulants remove polyethylene microplastics and humic acid from water. The study found that when humic acid adsorbs onto microplastic surfaces, it changes the removal dynamics, and polyaluminum chloride with hexagonal clusters achieved the best microplastic removal through adsorption bridging and sweeping mechanisms.
Improving nanoplastic removal by coagulation: Impact mechanism of particle size and water chemical conditions
Researchers found that coagulation using aluminum chlorohydrate and polyacrylamide achieved up to 98.5% removal efficiency for polystyrene nanoplastics, with smaller particles being easier to remove, though humic acid in water competed for adsorption sites and reduced effectiveness.
Elimination of a Mixture of Microplastics Using Conventional and Detergent-Assisted Coagulation
Researchers tested coagulation as a method to remove microplastics from tap water, evaluating how microplastic type (PE and PVC), water pH, coagulant dose, and microplastic concentration affect removal efficiency, and finding that detergent-assisted coagulation improves performance.
Enhanced Removal of Polystyrene Microplastics from Water Through Coagulation Using Polyaluminum Ferric Chloride with Coagulant Aids
Researchers tested enhanced coagulation using modified coagulants to remove polystyrene microplastics from water, finding that surface-modified coagulants achieved significantly higher removal efficiencies than conventional alum. Removal reached over 90% under optimized conditions, demonstrating a practical upgrade pathway for conventional water treatment plants to reduce microplastic discharge.
Removal characteristics of microplastics by Fe-based coagulants during drinking water treatment
The removal of polyethylene microplastics from drinking water was tested with Fe-based coagulants under various conditions, finding that traditional coagulation alone achieved below 15% removal, while coagulation combined with ultrafiltration substantially improved performance. The study identifies the limitations of conventional water treatment for microplastic removal and highlights ultrafiltration as a necessary add-on for effective particle reduction.