0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Remediation Sign in to save

The removal of microplastics from water by coagulation: A comprehensive review

The Science of The Total Environment 2022 151 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Wenhao Tang, Hua Li, Lianyue Fei, Bigui Wei, Tianhong Zhou, Hongwei Zhang

Summary

This review comprehensively examined coagulation as a technology for removing microplastics from drinking water and wastewater treatment plants, analyzing the mechanisms, influencing factors, and effectiveness of different coagulants for microplastic removal.

Study Type Environmental

Drinking water treatment plants (DWTPs) and wastewater treatment plants (WWTPs) are the first and last hurdles for the prevention of microplastics (MPs) pollution, respectively. With coagulation as one of the most critical technologies for the removal of MPs in water treatment plants, there is an urgent need to gain an in-depth understanding of the mechanisms and influencing factors of MPs removal during coagulation. In this paper, the research progress of adopting coagulation in MPs removal in recent years is reviewed, the removal effect of coagulation in water treatment plants are compared, and the role of three coagulation mechanisms, i.e., charge neutralization, adsorption bridging, and sweep flocculation in MPs removal process are identified. The effect of coagulant performance, MPs characteristics, operation conditions and other parameters on the removal of MPs are systematically analyzed. It is found that the combined coagulation techniques have better removal efficiency, can better decrease MP pollution and meet strict discharge standards. Moreover, flaws in the application of coagulation technology are pointed out, and strategies to deal with them are also proposed. Hopefully, this review can not only contribute to a better understanding of the mechanism of MPs removal by coagulation technology, but also serve as a useful guide for future research on MPs removal.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Coagulation technologies for separation of microplastics in water: current status

This review examines how coagulation water treatment technologies can remove microplastics from water. Conventional coagulation achieves 8-98% removal efficiency while electrocoagulation achieves 8-99%, depending on conditions, offering a potentially effective approach for reducing microplastics in drinking water and wastewater.

Article Tier 2

Microplastics removal by coagulation: cutting-edge coagulants and coagulation processes

This review examines how coagulation, a water treatment process that clumps particles together for easier removal, can be used to filter microplastics from water. Researchers summarize recent advances in coagulant materials, including novel hybrid formulations, and the factors that influence their effectiveness. The study highlights coagulation as a practical and scalable approach for addressing microplastic contamination in water treatment systems.

Meta Analysis Tier 1

Recent advances in microplastic removal from drinking water by coagulation: Removal mechanisms and influencing factors

A meta-analysis and random forest model found that coagulation can effectively remove microplastics from drinking water, with particle shape being the most important factor affecting removal efficiency, followed by coagulant type and dosage. Charge neutralization is the dominant mechanism for small microplastics, while adsorption bridging and sweeping work better for larger particles.

Article Tier 2

Treatment processes for microplastics and nanoplastics in waters: State-of-the-art review

This review summarized established and emerging treatment processes for removing microplastics and nanoplastics from drinking water and wastewater, evaluating coagulation, membrane filtration, advanced oxidation, and biological treatment in terms of removal efficiency and operational feasibility.

Article Tier 2

Microplastic removal by coagulation: a review of optimizing the reaction conditions and mechanisms

This review examines recent advances in using coagulation to remove microplastics from water and wastewater, analyzing how factors like coagulant type, dosage, pH, and particle shape affect removal efficiency. Researchers found that optimizing these reaction conditions is critical for maximizing microplastic removal while reducing energy costs. The study highlights significant knowledge gaps in understanding the mechanisms behind coagulation-based microplastic removal and calls for more extensive research.

Share this paper