0
Article Tier 2 Food & Water Remediation Sign in to save

Elimination of a Mixture of Microplastics Using Conventional and Detergent-Assisted Coagulation

Materials 2023 20 citations

AI summary Read the abstract

Researchers tested coagulation as a method to remove microplastics from tap water, evaluating how microplastic type (PE and PVC), water pH, coagulant dose, and microplastic concentration affect removal efficiency, and finding that detergent-assisted coagulation improves performance.

Polymers

The research described here investigated the suitability of coagulation process in the elimination of microplastics from tap water. The purpose of the study was to assess the effects of microplastic type (PE1, PE2, PE3, PVC1, PVC2, and PVC3), tap water pH (3, 5, 7, and 9), coagulant doses (0, 0.025, 0.05, 0.1 and 0.2 g/L), and microplastic concentration (0.05, 0.1, 0.15, and 0.2 g/L) on elimination efficiency with coagulation utilizing Al and Fe coagulants as well coagulation combined with a detergent (SDBS) addition. This work also explores the elimination of a mixture of two microplastics (PE and PVC) that are significant in terms of the environment. The effectiveness of conventional and detergent-assisted coagulation was calculated as a percentage. The fundamental characteristics of microplastics were also determined via LDIR analysis, and on the basis of these findings, particles that were more coagulation-prone were identified. The maximum reduction in MPs was achieved with tap water's neutral pH and a coagulant dosage of 0.05 g/L. The addition of SDBS increased the loss of the plastic microparticles' efficacy. A removal efficiency of greater than 95% (Al-coagulant) and 80% (Fe-coagulant) was achieved for each of the microplastics tested. The removal efficiency of the microplastic mixture with SDBS-assisted coagulation was obtained at a level of 95.92% (AlCl3·6H2O) and 98.9% (FeCl3·6H2O). After each coagulation procedure, the mean circularity and solidity of the unremoved particles increased. This confirmed that particles with irregular shapes are easier to completely remove.

More Papers Like This

Article Tier 2

Investigating the Potential of Coagulants to Improve Microplastics Removal in Wastewater and Tap Water

AI summary Read the abstract

Researchers found that adding coagulants (FeCl3 or Al2(SO4)3) to wastewater and tap water improved microplastic removal, with aluminum sulfate achieving 43% and 62% removal efficiencies respectively, though the high concentrations required suggest that combining coagulants with organic polyelectrolytes could improve practicality.

Article Tier 2

Understanding and Improving Microplastic Removal during Water Treatment: Impact of Coagulation and Flocculation

AI summary Read the abstract

Researchers systematically tested coagulation and flocculation for removing microplastics from drinking water, finding that removal efficiency depended strongly on plastic particle size and whether particles had been weathered, with smaller pristine particles being the hardest to remove.

Article Tier 2

Coagulation technologies for separation of microplastics in water: current status

AI summary Read the abstract

This review examines how coagulation water treatment technologies can remove microplastics from water. Conventional coagulation achieves 8-98% removal efficiency while electrocoagulation achieves 8-99%, depending on conditions, offering a potentially effective approach for reducing microplastics in drinking water and wastewater.

Article Tier 2

The removal of microplastics from water by coagulation: A comprehensive review

AI summary Read the abstract

This review comprehensively examined coagulation as a technology for removing microplastics from drinking water and wastewater treatment plants, analyzing the mechanisms, influencing factors, and effectiveness of different coagulants for microplastic removal.

Article Tier 2

The influence of coagulation process conditions on theefficiency of microplastic removal in water treatment

AI summary Read the abstract

Researchers investigated how coagulation process conditions — including coagulant type, pH, and microsand addition — affect the removal of polyethylene, PVC, and textile microfibers from river water, municipal wastewater, laundry effluent, and synthetic matrices. Ferric chloride and polyaluminum chloride both achieved substantial removal, with performance varying significantly by water matrix and microplastic type.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper