0
Article Tier 2 Detection Methods Environmental Sources Nanoplastics Policy & Risk Sign in to save

Sizing individual dielectric nanoparticles with quantitative differential interference contrast microscopy

AI summary Read the abstract

This paper presents a method using quantitative differential interference contrast (DIC) microscopy to accurately measure the size of individual dielectric nanoparticles, with potential application to nanoplastic sizing. The technique converts optical phase changes to intensity measurements, enabling precise single-particle sizing without fluorescent labels.

Polymers

We report a method to measure the size of single dielectric nanoparticles with high accuracy and precision using quantitative differential interference contrast (DIC) microscopy. Dielectric nanoparticles are detected optically by the conversion of the optical phase change into an intensity change using DIC. Phase images of individual nanoparticles were retrieved from DIC by Wiener filtering, and a quantitative methodology to extract nanoparticle sizes was developed. Using polystyrene beads of 100 nm radius as size standard, we show that the method determines this radius within a few nm accuracy. The smallest detectable polystyrene bead is limited by background and shot-noise, which depend on acquisition and analysis parameters, including the objective numerical aperture, the DIC phase offset, and the refractive index contrast between particles and their surrounding. A sensitivity limit potentially reaching down to 1.8 nm radius was inferred. As application example, individual nanodiamonds with nominal sizes below 50 nm were measured, and were found to have a nearly exponential size distribution with 28 nm mean value. Considering the importance of dielectric nanoparticles in many fields, from naturally occurring virions to polluting nanoplastics, the proposed method could offer a powerful quantitative tool for nanoparticle analysis, combining accuracy, sensitivity and high-throughput with widely available and easy-to-use DIC microscopy

More Papers Like This

Article Tier 2

Sizing individual dielectric nanoparticles with quantitative differential interference contrast microscopy

AI summary Read the abstract

Researchers developed a quantitative differential interference contrast (DIC) microscopy method to measure individual dielectric nanoparticle sizes with high accuracy, using polystyrene beads as standards to determine radii within a few nanometers, demonstrating sensitivity potentially reaching 1.8 nm and applying the technique to nanodiamond sizing and nanoplastic detection.

Article Tier 2

Photoinduced Force Microscopy as an Efficient Method Towards the Detection of Nanoplastics

AI summary Read the abstract

Researchers demonstrated photoinduced force microscopy as an effective method for detecting and chemically characterizing individual nanoplastic particles, overcoming limitations of conventional techniques that lack either sufficient spatial resolution or spectroscopic capability at the nanoscale.

Article Tier 2

Nanoparticle Tracking in Single-Antiresonant-Element Fiber for High-Precision Size Distribution Analysis of Mono- and Polydisperse Samples.

AI summary Read the abstract

This study presents a fiber-optic method for tracking individual nanoparticles with high precision to determine their size distribution. Using a specially designed microstructured fiber, researchers achieved more accurate sizing of nanoparticles than conventional light-scattering approaches. The technique has potential applications for characterizing nanoplastic particles in environmental samples.

Article Tier 2

Advanced Particle Size Analysis in High-Solid-Content Polymer Dispersions Using Photon Density Wave Spectroscopy

AI summary Read the abstract

Not relevant to microplastics research; this paper develops a new spectroscopic method for measuring the size of polymer nanoparticles in concentrated industrial dispersions, focused on manufacturing quality control rather than environmental microplastic pollution.

Article Tier 2

Real-time detection of label-free submicron-sized plastics using flow-channeled differential interference contrast microscopy

AI summary Read the abstract

Researchers developed differential interference contrast microscopy for real-time label-free detection of submicron plastics in water, overcoming bright-field microscopy limits.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper