A straightforward Py-GC/MS methodology for quantification of microplastics in tap water
Summary
Researchers developed a simpler, more affordable method for detecting and measuring microplastics in tap water using pyrolysis gas chromatography-mass spectrometry without needing expensive custom databases. The method successfully identified seven common polymer types in drinking water samples, making it easier for labs to monitor microplastic contamination in the water supply.
This study introduces a cost-effective and streamlined Pyrolysis Gas Chromatography-Mass Spectrometry (Py-GC/MS) methodology for detecting and quantifying microplastics in tap water, focusing on seven common polymers. Unlike conventional approaches relying on expensive pyrolyzate libraries, this method identifies pyrolysis fragments by matching their values with commercially available mass spectral libraries (Wiley Registry 12th Edition/NIST 2020) and confirms findings using pure polymer standards. Recovery was evaluated using two approaches, demonstrating that analysis of the entire filter provided more accurate results compared to extrapolation from subsections. The method exhibited excellent linearity for all targeted polymers (R² > 0.996) and achieved detection limits as low as 0.01 µg for polystyrene (PS) and up to 2.59 µg for polyethylene (PE). Application to tap water samples revealed consistent detection of PS, ranging from 2.532 to 2.571 ng/L in morning samples and 0.867 to 1.540 ng/L in afternoon samples, with polypropylene and PE below the limit of quantification (<LOQ). This method provides a reliable, efficient, and cost-effective tool for routine laboratory analysis of microplastics in tap water and other environmental matrices.•A 23-minute Py-GC/MS method efficiently quantifies microplastics in tap water.•Cost-effective strategy using commercially available mass spectral libraries.•Accurate quantification with ng/L sensitivity validated by pure polymer standards.
Sign in to start a discussion.
More Papers Like This
Routine method for the analysis of microplastics in natural and drinking water by pyrolysis coupled to gas chromatography-mass spectrometry
Researchers developed a standardized method to measure microplastics in drinking water using a technique called pyrolysis gas chromatography-mass spectrometry. They tested the method on river water, reclaimed water, and tap water in Barcelona, finding microplastic concentrations ranging from 11 to 77 micrograms per liter. Reliable detection methods like this are essential for understanding how much microplastic people are actually consuming through their drinking water.
Identification of Microplastics in Drinking Water Using Pyrolysis-GC/MS
Researchers used pyrolysis-GC/MS to identify and quantify microplastics by polymer mass (rather than particle count) in drinking water samples. The method detected multiple polymer types and provided mass-based metrics that are more toxicologically relevant than particle counts commonly reported in water quality studies.
Simultaneous determination of six microplastics in drinking water by pyrolysis-gas chromatography/mass spectrometry
Scientists developed an analytical method using pyrolysis-gas chromatography/mass spectrometry that can simultaneously detect and quantify six common types of microplastic in drinking water — including polyethylene, polypropylene, polystyrene, PET, PMMA, and PVC — with high sensitivity across a wide concentration range. Having a reliable, multi-polymer detection method is essential for monitoring drinking water safety and setting evidence-based regulatory limits.
Quantitative analysis of nanoplastics in environmental and potable waters by pyrolysis-gas chromatography–mass spectrometry
Scientists developed and validated a new method to detect and measure nine types of nanoplastics in drinking and environmental water at very low concentrations. They found nanoplastics in every water sample tested, with polyethylene, PET, polypropylene, and polystyrene being the most common at levels up to 1.17 micrograms per liter. This is one of the first studies to quantify nanoplastics in drinking water, confirming that people are regularly exposed through their tap water.
Identification and Quantification of Nanoplastics in Surface Water and Groundwater by Pyrolysis Gas Chromatography–Mass Spectrometry
Researchers developed a method combining ultrafiltration and pyrolysis gas chromatography-mass spectrometry to identify and quantify nanoplastics in surface water and groundwater. The study successfully detected six types of plastic polymers at the nanoscale in environmental water samples, providing much-needed quantitative data on nanoplastic pollution in real-world water sources.