0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Food & Water Sign in to save

A straightforward Py-GC/MS methodology for quantification of microplastics in tap water

MethodsX 2025 13 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count.
Alexander Ccanccapa-Cartagena, Anandu Nair Gopakumar, Anandu Nair Gopakumar, Maryam Salehi

Summary

Researchers developed a simpler, more affordable method for detecting and measuring microplastics in tap water using pyrolysis gas chromatography-mass spectrometry without needing expensive custom databases. The method successfully identified seven common polymer types in drinking water samples, making it easier for labs to monitor microplastic contamination in the water supply.

This study introduces a cost-effective and streamlined Pyrolysis Gas Chromatography-Mass Spectrometry (Py-GC/MS) methodology for detecting and quantifying microplastics in tap water, focusing on seven common polymers. Unlike conventional approaches relying on expensive pyrolyzate libraries, this method identifies pyrolysis fragments by matching their values with commercially available mass spectral libraries (Wiley Registry 12th Edition/NIST 2020) and confirms findings using pure polymer standards. Recovery was evaluated using two approaches, demonstrating that analysis of the entire filter provided more accurate results compared to extrapolation from subsections. The method exhibited excellent linearity for all targeted polymers (R² > 0.996) and achieved detection limits as low as 0.01 µg for polystyrene (PS) and up to 2.59 µg for polyethylene (PE). Application to tap water samples revealed consistent detection of PS, ranging from 2.532 to 2.571 ng/L in morning samples and 0.867 to 1.540 ng/L in afternoon samples, with polypropylene and PE below the limit of quantification (<LOQ). This method provides a reliable, efficient, and cost-effective tool for routine laboratory analysis of microplastics in tap water and other environmental matrices.•A 23-minute Py-GC/MS method efficiently quantifies microplastics in tap water.•Cost-effective strategy using commercially available mass spectral libraries.•Accurate quantification with ng/L sensitivity validated by pure polymer standards.

Share this paper