0
Article Tier 2 Detection Methods Environmental Sources Food & Water Human Health Effects Marine & Wildlife Policy & Risk Remediation Sign in to save

Routine method for the analysis of microplastics in natural and drinking water by pyrolysis coupled to gas chromatography-mass spectrometry

Journal of Chromatography A 2024 19 citations

AI summary Read the abstract

Researchers developed a standardized method to measure microplastics in drinking water using a technique called pyrolysis gas chromatography-mass spectrometry. They tested the method on river water, reclaimed water, and tap water in Barcelona, finding microplastic concentrations ranging from 11 to 77 micrograms per liter. Reliable detection methods like this are essential for understanding how much microplastic people are actually consuming through their drinking water.

Study Type Environmental

The presence of microplastics (MPs) in water intended for human consumption represents a growing concern due to their ubiquity in the aquatic environments and the potential adverse effects on human health. In this context, validated and standardized analytical methods are required to minimize uncertainties associated with the determination of MPs in water, especially during the drinking water treatment process. In this study, a simple water sampling and extraction procedure and analysis using pyrolysis with gas chromatography coupled to mass spectrometry (Py-GC-MS) was developed to determine 7 types of polymers in water. Quality parameters associated with the method were evaluated, including limits of detection (MDL) and quantitation (MQL), linearity, precision, accuracy, and extended uncertainty. The developed methodology was validated by participating in the EUROQCHARM interlaboratory exercise, and the Z-scores were within the acceptable range for 4 of the 5 polymers tested. Finally, MPs were determined in river water, reclaimed water, and drinking water from the urban area of Barcelona and total concentrations ranged from 11.3 µg/L to 77.1 µg/L. The proposed methodology allows for simple (direct filtration of 100-500 mL of water with a 13 mm glass fiber filter), quantitative (µg/L), and rapid (with a total analysis time of 20 min per sample, including both pyrolysis and GC-MS) analysis of MPs in water intended for drinking.

More Papers Like This

Article Tier 2

A straightforward Py-GC/MS methodology for quantification of microplastics in tap water

AI summary Read the abstract

Researchers developed a simpler, more affordable method for detecting and measuring microplastics in tap water using pyrolysis gas chromatography-mass spectrometry without needing expensive custom databases. The method successfully identified seven common polymer types in drinking water samples, making it easier for labs to monitor microplastic contamination in the water supply.

Article Tier 2

Identification of Microplastics in Drinking Water Using Pyrolysis-GC/MS

AI summary Read the abstract

Researchers used pyrolysis-GC/MS to identify and quantify microplastics by polymer mass (rather than particle count) in drinking water samples. The method detected multiple polymer types and provided mass-based metrics that are more toxicologically relevant than particle counts commonly reported in water quality studies.

Article Tier 2

Implementation plan to monitor microplastics in surface and drinking water using Py-GC-MS according to Decision (EU) 2024/1441

AI summary Read the abstract

Researchers developed and applied a monitoring method for detecting six common plastic polymers in surface water and drinking water from Barcelona's main water supply, the Llobregat River basin. Using pyrolysis-gas chromatography mass spectrometry, they detected microplastics in both river water and the city's drinking water distribution network. The study provides a practical implementation plan aligned with new EU regulations for routine microplastic monitoring in drinking water.

Article Tier 2

Simultaneous determination of six microplastics in drinking water by pyrolysis-gas chromatography/mass spectrometry

AI summary Read the abstract

Scientists developed an analytical method using pyrolysis-gas chromatography/mass spectrometry that can simultaneously detect and quantify six common types of microplastic in drinking water — including polyethylene, polypropylene, polystyrene, PET, PMMA, and PVC — with high sensitivity across a wide concentration range. Having a reliable, multi-polymer detection method is essential for monitoring drinking water safety and setting evidence-based regulatory limits.

Article Tier 2

Microplastics in drinking water: quantitative analysis of microplastics from source to tap by pyrolysis–gas chromatography-mass spectrometry

AI summary Read the abstract

Researchers used pyrolysis–GC-MS to quantify microplastics by mass concentration at each stage of Amsterdam's drinking water supply—from raw surface water through two treatment plants to household tap water—providing rare mass-based data on MP fate during treatment.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper