We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
The Fate of Microplastics During Physicochemical and Biological Wastewater Treatment: A Critical Review of Pathways and Mechanisms
AI summary Read the abstract
This review summarizes existing research on how wastewater treatment plants handle microplastics, most commonly fibers. Removal varied widely by method: membrane-based systems and anaerobic-anoxic-oxic membrane bioreactors removed over 91%, electrocoagulation removed 70 to 95%, and traditional biological treatment removed over 65%.
Microplastics (MPs) are persistent contaminants in wastewater, with wastewater treatment plants (WWTPs) serving as both sinks and pathways to aquatic systems. This review evaluates the sources and characteristics of MPs and critically assesses the performance, mechanisms, and limitations of their removal during wastewater treatment. The literature was critically examined to compare conventional and emerging treatment technologies and identify the operational factors governing MP removal. MPs in wastewater originate mainly from domestic and industrial activities, with fibers consistently being the main component. Typically, polyethylene, polypropylene, polyethylene terephthalate, and polystyrene were the most frequently identified polymer types. MP removal was influenced by pH and TSS, although their effects varied with treatment configuration and wastewater characteristics. Physical treatment operations exhibited highly variable microplastic removal efficiencies across treatment units and operational conditions, whereas membrane-based systems frequently achieved removal efficiencies exceeding 99%. Electrocoagulation–electroflotation systems have demonstrated 70–95% MP removal efficiency in laboratory and pilot-scale studies, whereas adsorption and advanced oxidation processes have primarily been investigated for refined treatment. Traditional biological treatment systems generally showed over 65% microplastic removal, whereas full-scale anaerobic–anoxic–oxic membrane bioreactors achieved 91–96% removal. The mixed liquor suspended solids and solids retention time also influenced the extracellular polymeric substance-mediated capture of MPs. In summary, WWTPs substantially reduce MPs, and careful application of respective systems can significantly reduce MPs in the treated effluent.
More Papers Like This
A comprehensive review of microplastics in wastewater treatment plants
AI summary Read the abstract
This review surveys microplastic removal technologies used in wastewater treatment plants, comparing membrane bioreactors, electrocoagulation, coagulation-sedimentation, and biodegradation approaches. Understanding removal efficiency at treatment plants is critical because they are a primary pathway by which microplastics — and the toxic chemicals they carry — reach rivers, coastal waters, and ultimately drinking water supplies.
Micro- and nanoplastics removal mechanisms in wastewater treatment plants: A review
AI summary Read the abstract
This review examines how conventional wastewater treatment plants remove micro- and nanoplastics, and evaluates advanced technologies like membrane filtration and electrocoagulation that could improve removal rates. While existing treatment plants can capture most microplastics, they still release significant quantities into waterways through their enormous discharge volumes. The study highlights that biological treatment steps may also transform microplastics in potentially harmful ways that need further investigation.
Eradication of Microplastics in Wastewater Treatment: Overview
AI summary Read the abstract
This review examined technologies for removing microplastics from wastewater, evaluating physical, chemical, and biological treatment methods and finding that while conventional treatment plants capture a significant fraction, emerging technologies like membrane filtration and coagulation are needed to achieve more complete removal.
Interactions between microplastics and unit processes of wastewater treatment plants: a critical review
AI summary Read the abstract
This critical review examines how microplastics interact with each unit process in wastewater treatment plants, synthesizing removal efficiencies and identifying that while conventional treatment removes the majority of microplastics, small particles and fibers consistently pass through to effluent.
Influence of wastewater treatment process on pollution characteristics and fate of microplastics
AI summary Read the abstract
Researchers investigated microplastic abundance and removal efficiency across four wastewater treatment plants using different treatment technologies, finding influent concentrations between 539 and 1,290 particles per liter that were reduced substantially by primary and secondary treatment. Smaller microplastic particles proved hardest to remove and most likely to persist in final effluent.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.