We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Identification and Quantification of Microplastics in Wastewater Using Focal Plane Array-Based Reflectance Micro-FT-IR Imaging
AI summary Read the abstract
Researchers applied focal plane array FT-IR imaging to identify and quantify microplastics in wastewater samples, demonstrating that this method provides efficient and detailed polymer characterization across large sample areas.
Microplastics (<5 mm) have been documented in environmental samples on a global scale. While these pollutants may enter aquatic environments via wastewater treatment facilities, the abundance of microplastics in these matrices has not been investigated. Although efficient methods for the analysis of microplastics in sediment samples and marine organisms have been published, no methods have been developed for detecting these pollutants within organic-rich wastewater samples. In addition, there is no standardized method for analyzing microplastics isolated from environmental samples. In many cases, part of the identification protocol relies on visual selection before analysis, which is open to bias. In order to address this, a new method for the analysis of microplastics in wastewater was developed. A pretreatment step using 30% hydrogen peroxide (H2O2) was employed to remove biogenic material, and focal plane array (FPA)-based reflectance micro-Fourier-transform (FT-IR) imaging was shown to successfully image and identify different microplastic types (polyethylene, polypropylene, nylon-6, polyvinyl chloride, polystyrene). Microplastic-spiked wastewater samples were used to validate the methodology, resulting in a robust protocol which was nonselective and reproducible (the overall success identification rate was 98.33%). The use of FPA-based micro-FT-IR spectroscopy also provides a considerable reduction in analysis time compared with previous methods, since samples that could take several days to be mapped using a single-element detector can now be imaged in less than 9 h (circular filter with a diameter of 47 mm). This method for identifying and quantifying microplastics in wastewater is likely to provide an essential tool for further research into the pathways by which microplastics enter the environment.
More Papers Like This
Focal plane array detector-based micro-Fourier-transform infrared imaging for the analysis of microplastics in environmental samples
AI summary Read the abstract
Researchers developed an automated protocol using focal plane array FT-IR imaging to identify and count microplastics on filters without manual sorting, dramatically increasing throughput compared to manual methods. The approach represents an important step toward standardized, high-throughput microplastic monitoring in aquatic environments.
Classification and Quantification of Microplastics (<100 μm) Using a Focal Plane Array–Fourier Transform Infrared Imaging System and Machine Learning
AI summary Read the abstract
Researchers developed a method using focal plane array Fourier transform infrared imaging to classify and quantify microplastics smaller than 100 micrometers. The technique allows simultaneous chemical identification and size measurement of individual particles across a filter sample, significantly improving throughput compared to manual analysis. The study demonstrates that automated spectroscopic imaging can reliably detect and categorize very small microplastics that are often missed by conventional methods.
Microplastic Mass Quantification Using Focal Plane Array-Based Micro-Fourier-Transform Infrared Imaging
AI summary Read the abstract
Researchers developed a method using focal plane array Fourier-transform infrared imaging to quantify microplastic mass by estimating particle volume from Beer's law absorption at each pixel, enabling three-dimensional geometry characterization. The approach provides more accurate mass-based quantification than counting or area methods alone.
An automated approach for microplastics analysis using focal plane array (FPA) FTIR microscopy and image analysis
AI summary Read the abstract
Researchers developed an automated approach using focal plane array FT-IR spectroscopy for microplastic analysis, enabling faster and more comprehensive identification of particles in environmental samples with less manual effort.
Quantification of microplastic mass and removal rates at wastewater treatment plants applying Focal Plane Array (FPA)-based Fourier Transform Infrared (FT-IR) imaging
AI summary Read the abstract
This study quantified microplastic mass and calculated removal rates at wastewater treatment plants, finding that while plants remove a large proportion of incoming microplastics, the residual discharge still represents a substantial ongoing input to receiving water bodies.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.