We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Extending theLinear Dynamic Range of Single ParticleICP-MS for the Quantification of Microplastics
AI summary Read the abstract
Researchers extended the linear dynamic range of single-particle ICP-MS for microplastic quantification to enable detection across a wider concentration range with high throughput. The method improvements allow more accurate characterisation of MP particle number and size distributions in environmental and biological samples.
In response to the growing concern of microplastics (1 μm to 5 mm) accumulation affecting human health, the development of analytical methods continues to be critical for the detection and characterization of microplastic particles. In this context, pursuing exceptional particle detection capability down to practical low levels and rapid analyses with high sample throughput makes single particle inductively coupled plasma mass spectrometry (spICP-MS) very attractive for microplastics analysis. Existing spICP-MS-based studies have routinely shown limitations in the accurate sizing and quantification of particle number concentration through targeting carbon content, with reported size limits of detection in the range of 0.62 to 1.8 μm and a substantial reduction in the transport of particles larger than 3 μm. In this work, the linear dynamic range of spICP-MS for the accurate quantification of polystyrene microparticles (PS MPs) via the monitoring of their carbon content (13C+) is extended to larger particle sizes (5 μm) through using a high efficiency sample introduction system with rigorous optimization of the 13C signal and operating at a lowered nebulizer gas flow to improve sample transport of larger particles to the plasma. Reliable quantification of particle number concentration (PNC), accepted as falling within 20% of expected particle stock concentrations, was achieved through a 20% lowered nebulizer gas flow for a full suite of commercial PS MPs ranging from 2 to 5 μm as well as a 2.2 and 4.8 μm PS MP contained within mixtures of the two materials, regardless of PNC ratio.
More Papers Like This
Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics
AI summary Read the abstract
Researchers developed an improved method using single particle inductively coupled plasma mass spectrometry to detect and measure microplastics across a wider size range than previously possible. By extending the linear dynamic range of the technique, they could more accurately size and count larger microplastic particles. The advancement addresses a key limitation in current microplastic analytical methods and could improve environmental monitoring.
Multimethod Platform Based on Dynamic Image Analysis and spICP-MS for Number-Based Quantification of Microplastics
AI summary Read the abstract
Researchers developed and validated a multimethod analytical platform combining dynamic image analysis and single-particle ICP-MS to reliably quantify the number concentration of small microplastics (1-10 µm), a size range that has been difficult to measure accurately with existing methods.
MultimethodPlatform Based on Dynamic Image Analysisand spICP-MS for Number-Based Quantification of Microplastics
AI summary Read the abstract
Researchers developed and validated a multimethod platform combining dynamic image analysis (DIA) and single-particle ICP-MS (spICP-MS) for reliably quantifying the number concentration of small microplastics (1-10 µm), identifying critical instrument parameters that affect measurement accuracy for each technique.
Investigation and correction of size-dependent transport efficiencies of microparticles in SP ICP-MS analysis.
AI summary Read the abstract
Researchers systematically measured how single-particle ICP-MS transport efficiency declines sharply for microplastics above 3 µm in diameter — a size range where conventional constant-TE assumptions break down — and developed a sigmoidal correction model using flow cytometry as an independent reference, showing that without this correction both particle size distributions and number concentrations are systematically biased toward smaller particles.
Single-Particle ICP-TOFMS with Online Microdroplet Calibration: A Versatile Approach for Accurate Quantification of Nanoparticles, Submicron Particles, and Microplastics in Seawater
AI summary Read the abstract
Online microdroplet calibration was used with single-particle ICP-TOFMS to overcome matrix effects and achieve accurate multi-element quantification in nanoparticle and microparticle samples, demonstrating a versatile approach for environmental and industrial nanoparticle analysis.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.