0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Human Health Effects Policy & Risk Sign in to save

Extending theLinear Dynamic Range of Single ParticleICP-MS for the Quantification of Microplastics

Figshare 2025 Score: 48 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
George C. Caceres (22188622), Monique E. Johnson (3604595), John L. Molloy (1267830), Sang Bok Lee (1416703), Antonio R. Montoro Bustos (12075796)

Summary

Researchers extended the linear dynamic range of single-particle ICP-MS for microplastic quantification to enable detection across a wider concentration range with high throughput. The method improvements allow more accurate characterisation of MP particle number and size distributions in environmental and biological samples.

Polymers

In response to the growing concern of microplastics (1 μm to 5 mm) accumulation affecting human health, the development of analytical methods continues to be critical for the detection and characterization of microplastic particles. In this context, pursuing exceptional particle detection capability down to practical low levels and rapid analyses with high sample throughput makes single particle inductively coupled plasma mass spectrometry (spICP-MS) very attractive for microplastics analysis. Existing spICP-MS-based studies have routinely shown limitations in the accurate sizing and quantification of particle number concentration through targeting carbon content, with reported size limits of detection in the range of 0.62 to 1.8 μm and a substantial reduction in the transport of particles larger than 3 μm. In this work, the linear dynamic range of spICP-MS for the accurate quantification of polystyrene microparticles (PS MPs) via the monitoring of their carbon content (13C+) is extended to larger particle sizes (5 μm) through using a high efficiency sample introduction system with rigorous optimization of the 13C signal and operating at a lowered nebulizer gas flow to improve sample transport of larger particles to the plasma. Reliable quantification of particle number concentration (PNC), accepted as falling within 20% of expected particle stock concentrations, was achieved through a 20% lowered nebulizer gas flow for a full suite of commercial PS MPs ranging from 2 to 5 μm as well as a 2.2 and 4.8 μm PS MP contained within mixtures of the two materials, regardless of PNC ratio.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

Researchers developed an improved method using single particle inductively coupled plasma mass spectrometry to detect and measure microplastics across a wider size range than previously possible. By extending the linear dynamic range of the technique, they could more accurately size and count larger microplastic particles. The advancement addresses a key limitation in current microplastic analytical methods and could improve environmental monitoring.

Article Tier 2

Multimethod Platform Based on Dynamic Image Analysis and spICP-MS for Number-Based Quantification of Microplastics

Researchers developed and validated a multimethod analytical platform combining dynamic image analysis and single-particle ICP-MS to reliably quantify the number concentration of small microplastics (1-10 µm), a size range that has been difficult to measure accurately with existing methods.

Article Tier 2

MultimethodPlatform Based on Dynamic Image Analysisand spICP-MS for Number-Based Quantification of Microplastics

Researchers developed and validated a multimethod platform combining dynamic image analysis (DIA) and single-particle ICP-MS (spICP-MS) for reliably quantifying the number concentration of small microplastics (1-10 µm), identifying critical instrument parameters that affect measurement accuracy for each technique.

Article Tier 2

Single-Particle ICP-TOFMS with Online Microdroplet Calibration: A Versatile Approach for Accurate Quantification of Nanoparticles, Submicron Particles, and Microplastics in Seawater

Online microdroplet calibration was used with single-particle ICP-TOFMS to overcome matrix effects and achieve accurate multi-element quantification in nanoparticle and microparticle samples, demonstrating a versatile approach for environmental and industrial nanoparticle analysis.

Article Tier 2

Nanoplastics prepared with uniformly distributed metal-tags: a novel approach to quantify size distribution and particle number concentration of polydisperse nanoplastics by single particle ICP-MS

Researchers developed a new method for creating nanoplastic test particles with embedded metal tags, allowing scientists to precisely measure the size and number of nanoplastics using single-particle mass spectrometry. The particles have realistic irregular shapes and varied sizes, unlike the uniform spheres typically used in lab studies. This tool will help researchers more accurately study how nanoplastics behave in environmental and health experiments.

Share this paper