0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Sign in to save

Multimethod Platform Based on Dynamic Image Analysis and spICP-MS for Number-Based Quantification of Microplastics

Analytical Chemistry 2025 Score: 38 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Aneta Sikora, David Ojeda, Dorota Bartczak, Heidi Goenaga‐Infante

Summary

Researchers developed and validated a multimethod analytical platform combining dynamic image analysis and single-particle ICP-MS to reliably quantify the number concentration of small microplastics (1-10 µm), a size range that has been difficult to measure accurately with existing methods.

Polymers

A multimethod platform based on the combination of dynamic image analysis (DIA) and single particle inductively coupled plasma mass spectrometry (spICP-MS) has been developed, validated, and applied for the first time to reliably determine the particle number concentration of small microplastics. The ability of the DIA/spICP-MS platform to reliably detect and quantify microplastics was carefully studied using polystyrene (PS) microparticles in the size range from 1 to 10 μm. Critical instrumental parameters affecting the accuracy of the number-concentration measurements were identified for both techniques. In the case of DIA, the detection threshold (DT) was found to be the most important, while for spICP-MS, both the calibration of the transport efficiency (TE) using the frequency method and the choice of sample introduction system were critical. Under optimal conditions, the number-concentration values obtained for 5 μm PS-Latex microspheres using DIA and spICP-MS methodologies agreed well within their associated uncertainty (u, k = 1 of approximately 2.5% for DIA and u, k = 1 of approximately 10.2% for spICP-MS). Main contributing factors to the overall measurement uncertainty were evaluated for methodology based on both techniques, being the variability in the number of detected particles for DIA and the number of detected particles and transport efficiency calibration for spICP-MS. These accounted for approximately 94% (DIA) and approximately 45% (spICP-MS) of the overall uncertainty budget, respectively.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

MultimethodPlatform Based on Dynamic Image Analysisand spICP-MS for Number-Based Quantification of Microplastics

Researchers developed and validated a multimethod platform combining dynamic image analysis (DIA) and single-particle ICP-MS (spICP-MS) for reliably quantifying the number concentration of small microplastics (1-10 µm), identifying critical instrument parameters that affect measurement accuracy for each technique.

Article Tier 2

Extending theLinear Dynamic Range of Single ParticleICP-MS for the Quantification of Microplastics

Researchers extended the linear dynamic range of single-particle ICP-MS for microplastic quantification to enable detection across a wider concentration range with high throughput. The method improvements allow more accurate characterisation of MP particle number and size distributions in environmental and biological samples.

Article Tier 2

Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

Researchers developed an improved method using single particle inductively coupled plasma mass spectrometry to detect and measure microplastics across a wider size range than previously possible. By extending the linear dynamic range of the technique, they could more accurately size and count larger microplastic particles. The advancement addresses a key limitation in current microplastic analytical methods and could improve environmental monitoring.

Article Tier 2

The power of a multi-technique approach for the reliable quantification of microplastics in water

Researchers applied a multi-technique analytical approach combining several spectroscopic and microscopic methods to improve the reliability of microplastic quantification in environmental samples. The combined approach reduced false positives and improved polymer identification accuracy compared to any single method used alone.

Article Tier 2

Direct Measurement of Microplastics by Carbon Detection via Single Particle ICP-TOFMS in Complex Aqueous Suspensions

Researchers developed a single particle ICP-TOFMS method for directly measuring microplastics in complex aqueous suspensions by detecting carbon, successfully differentiating microplastic carbon from natural particles and dissolved organic carbon in environmental samples.

Share this paper