0
Article Tier 2 Detection Methods Food & Water Human Health Effects Remediation Sign in to save

A Selective Ratiometric Fluorescent Probe for No-Wash Detection of PVC Microplastic

Polymers 2021 17 citations

AI summary Read the abstract

Researchers developed a selective ratiometric fluorescent probe for detecting PVC microplastics without sample washing, offering a simpler and faster method than current spectroscopic approaches for identifying this specific polymer type in water.

Study Type Environmental

Microplastics (MP) are micrometric plastic particles present in drinking water, food and the environment that constitute an emerging pollutant and pose a menace to human health. Novel methods for the fast detection of these new contaminants are needed. Fluorescence-based detection exploits the use of specific probes to label the MP particles. This method can be environmentally friendly, low-cost, easily scalable but also very sensitive and specific. Here, we present the synthesis and application of a new probe based on perylene-diimide (PDI), which can be prepared in a few minutes by a one-pot reaction using a conventional microwave oven and can be used for the direct detection of MP in water without any further treatment of the sample. The green fluorescence is strongly quenched in water at neutral pH because of the formation dimers. The ability of the probe to label MP was tested for polyvinyl chloride (PVC), polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), poly methyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE). The probe showed considerable selectivity to PVC MP, which presented an intense red emission after staining. Interestingly, the fluorescence of the MP after labeling could be detected, under excitation with a blue diode, with a conventional CMOS color camera. Good selectivity was achieved analyzing the red to green fluorescence intensity ratio. UV-Vis absorption, steady-state and time-resolved fluorescence spectroscopy, fluorescence anisotropy, fluorescence wide-field and confocal laser scanning microscopy allowed elucidating the mechanism of the staining in detail.

More Papers Like This

Article Tier 2

A Selective Fluorescent Probe for the Specific Detection of Polyvinyl Chloride (PVC) Microplastics in Monitoring Environmental Pollution for Human Health

AI summary Read the abstract

Researchers developed a selective fluorescent probe called MA12C, an acridone derivative, capable of detecting polyvinyl chloride (PVC) microplastics with high specificity via a fluorescence turn-on mechanism, offering a new tool for environmental monitoring of PVC contamination in water.

Article Tier 2

Frequency domain fluorescence lifetime imaging microscopy: A new method to directly identify microplastics in water.

AI summary Read the abstract

Researchers evaluated frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) as a method to identify ABS, PC, PET, PS, and PVC granulates directly in a 1 cm water layer without filtration or drying. The study found that all five polymer types could be unambiguously identified by their fluorescence lifetimes, establishing FD-FLIM as a promising rapid label-free technique for direct microplastic detection in aqueous samples.

Article Tier 2

A New Optical Method for Quantitative Detection of Microplastics in Water Based on Real-Time Fluorescence Analysis

AI summary Read the abstract

Researchers developed a new fluorescence-based particle counter for real-time quantitative detection of microplastics in water, validating the method against FTIR analysis on wastewater treatment plant samples containing polyethylene and PVC particles.

Article Tier 2

Optical measurement technologies for detecting low levels of pollution and identifying microplastics in water

AI summary Read the abstract

Researchers reviewed optical technologies for detecting and identifying microplastics in water, experimentally characterizing the fluorescence spectra of PE and PET microplastic samples under 365 nm excitation and identifying spectral bands enabling identification of different polymer types, then proposing a comprehensive hardware solution using a fluorescent probe for microplastic visualization.

Article Tier 2

Selective Recognition and Portable Quantification of PVC Microplastics Using a Water-Soluble AIE Fluorescent Probe

AI summary Read the abstract

Scientists created a special glow-in-the-dark dye that lights up specifically when it touches PVC microplastics—a common but concerning type of plastic pollution—in water samples like tap water, lake water, and even seawater. This matters because right now it's hard to quickly identify which type of microplastic is contaminating our water, and this simple test could help researchers track PVC pollution (which can release harmful chemical additives) more easily, without needing complicated lab equipment. While this study focused on detection technology rather than health effects directly, better tools like this are an important step toward understanding and monitoring our exposure to potentially harmful plastics

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper