We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Simple screening of microplastics in bottled waters and environmental freshwaters using a novel fluorophore
Summary
Researchers developed a rapid fluorescence-based screening method for microplastics using the novel fluorophore 1-pyrenebutyric acid N-hydroxysuccinimidyl ester (PBN), which stained diverse synthetic polymer types within 5 minutes and successfully detected microplastics in bottled water and environmental freshwater samples.
Screening of polymeric microplastic debris can help to assess the extent to which plastics contaminate the environment. We here developed an easy- and rapid-to-perform method for the screening of plastic polymers, based on a newly employed fluorophore, namely 1-pyrenebutyric acid N-hydroxysuccinimidyl ester (PBN). The PBN fluorophore was capable of staining diverse synthetic microplastic polymers within 5 min, including those displaying various particle sizes and shapes. The fluorescence intensities of the microplastics were considerably enhanced after the short-duration staining. The screening method was shown to be highly effective in the detection of polyethylene (PE), poly(ethylene terephthalate) (PET), polyvinyl chloride (PVC), polyamide-6 (PA-6), polypropylene (PP), polystyrene (PS), polycarbonate (PC), polyvinylidenechloride (PVDC), and polyurethane (PU), with a lowest analyzed particle size of 15 μm. Using our screening method, plastic contamination was investigated in commercially available bottled waters and environmental waters, specifically urban freshwaters. This study demonstrated high affinity levels of the newly proposed PBN fluorophore for a broad range of polymers and its ability to be used to discernibly identify polymer particles.
Sign in to start a discussion.
More Papers Like This
Rapid and reliable detection of microplastics in drinking water using fluorescence microscopy
This study developed a rapid and reliable fluorescence-based method for detecting microplastics in drinking water, addressing the need for faster alternatives to time-consuming conventional analytical approaches. The method demonstrated high sensitivity and specificity for common plastic polymers in drinking water matrices.
Fast and portable fluorescence lifetime analysis for early warning detection of micro- and nanoplastics in water
Researchers developed a portable fluorescence-based system that can detect micro- and nanoplastics in water without any sample preparation or labeling. The method works by measuring the natural fluorescence lifetime of plastic particles using a pulsed laser, achieving detection limits as low as 0.01 mg/mL. The study presents a promising early-warning tool for rapid, on-site monitoring of plastic contamination in water sources.
Rapid and reliable detection of microplastics in drinking water using fluorescence microscopy
Researchers developed a fluorescence-based method for rapid detection and quantification of microplastics in drinking water, addressing the need for faster and more practical monitoring tools. The method achieved high sensitivity and allowed polymer discrimination without requiring expensive spectroscopic instrumentation.
A new method for counting and sizing microplastic particles in water: investigating the presence of microplastics in Iranian bottled water
Researchers developed a novel method for counting and sizing microplastic particles in bottled water using Nile Red fluorescent staining combined with direct microscopic counting. Testing Iranian bottled water brands revealed widespread microplastic contamination, with the new method providing a faster and more accessible alternative to spectroscopic identification for routine bottled water monitoring.
Frequency domain fluorescence lifetime imaging microscopy: A new method to directly identify microplastics in water.
Researchers evaluated frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) as a method to identify ABS, PC, PET, PS, and PVC granulates directly in a 1 cm water layer without filtration or drying. The study found that all five polymer types could be unambiguously identified by their fluorescence lifetimes, establishing FD-FLIM as a promising rapid label-free technique for direct microplastic detection in aqueous samples.