0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Policy & Risk Remediation Sign in to save

Funktion hos enskilda anläggningar och en grön vägg för behandling av bad-, disk- och tvättvatten

KTH Publication Database DiVA (KTH Royal Institute of Technology) 2023 Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Sami, Mashreki

Summary

This Swedish thesis examines the performance of decentralized greywater treatment systems including constructed wetlands and green walls, assessing their ability to remove pollutants including microplastics from household wastewater.

Greywater contains inorganic and organic substances, nutrients, pathogens, micropollutants and microplastics. Source-separated greywater using decentralized systems can potentially provide energy-efficient and low-maintenance treatment. If effectively treated, greywater could be a source for non-potable water use in for instance urban landscaping or agricultural irrigation. The overall aim of this thesis was to investigate the treatment efficiencies of two different types of decentralized greywater treatment systems: a) on-site package plants and b) a nature-based solution (NBS) - green wall. These two different treatment systems were assessed based on their removal efficiency of organic matter (BOD, COD, TOC), nutrients (nitrogen (N) and phosphorus (P)), surfactants, indicator bacteria (E. coli and enterococci) as well as microplastics. The study of the on-site package plants investigated eight on-site greywater treatment facilities of four different types (A, B, C and D). Systems types A-C were commercially available and type D was an onsite built sand filter. The treatment unit of type A consisted of a trickling filter fitted with geotextile resting on a sand filter bed. The treatment unit of type B included a fibrous mineral wool filter material while type C contained a series of fine-meshed plastic filters. Prior to types A, B and D, septic tanks were located to contribute with pre-treatment, whereas type C, the smallest system investigated, included a septic tank within the treatment unit. >90% removal of organic matter (BOD and COD) was achieved by types A and D, but the N removal was comparatively higher by type B (44-68%). Effective P removal was only observed in type D (56%). However, the effluent concentration from all the systems was <3mg/l. The treatment efficiency of type C was found to be relatively low. In the green wall study, the efficiency of five filter materials (pumice, biochar, hemp fiber, spent coffee ground (SCG) and compost fiber soil) were evaluated with regards to hydraulic loading rates (HLRs) (4.5, 9, and 18 l/d). The treatment efficiency varied significantly with materials and HLRs. Biochar consistently removed 99% of BOD for all HLRs. High N removal (>80%) was observed by pumice and biochar during the high HLR (18 l/d). However, P removal by hemp was comparatively higher (75-85%) than by biochar and pumice. SCG and compost soil was tested with only 4.5 l/d, where compost soil showed effective treatment of BOD (99%), N (82%) and P (85%). SCG was the least effective material releasing more organics and nutrients in the effluent. Both the studies showed high concentration (>105 cfu/100 ml) of E. coli and enterococci in the influent and effluent greywater. The treatment systems were in general not effective in removing E.coli and enterococci. The most efficient system was the sand filter (D), achieving 1.4-3.8 log10 E.coli reduction and 2.3-3.3 log10 reduction for enterococci. Biochar achieved similar removal at HRL 4.5 l/d. Using thermal extraction desorption gas chromatography-mass spectrometry (TED-GCMS) technique, polyvinylchloride, polystyrene, poly-ethylene-terephthalate, polyethylene, polypropylene, and polyamide 6 were detected in the influent and effluent greywater in both studies. Even though there was variability in the influent concentrations, low concentrations were observed in the effluents, suggesting the systems were effective in retaining the microplastics.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Rening av dagvatten med en kompakt reningsanläggning

Researchers investigated compact underground stormwater treatment systems as a space-efficient alternative to conventional stormwater ponds in dense urban environments, evaluating their performance in removing pollutants including microplastics from urban runoff.

Article Tier 2

Microplastics occurrence and fate in full-scale treatment wetlands

Researchers assessed microplastic occurrence and fate across full-scale treatment wetlands, finding that constructed wetlands effectively remove a significant proportion of MPs from wastewater but that removal efficiency varies with wetland design and MP characteristics.

Article Tier 2

The Occurrence and Removal of Microplastics from Stormwater Using Green Infrastructure

This review examines microplastic occurrence in urban stormwater and the potential of green infrastructure — particularly bioretention systems and constructed wetlands — to capture and remove plastic particles before they reach surface water bodies.

Article Tier 2

Microplastics profile in constructed wetlands: Distribution, retention and implications

This study assessed microplastic distribution, retention, and implications within constructed wetlands used for wastewater treatment, finding that wetlands trap substantial quantities of MPs but that retention efficiency varies by plant species and wetland design. The results suggest constructed wetlands both remove and potentially accumulate MPs as a secondary pollution source.

Article Tier 2

Microplastic Identification in Domestic Wastewater-Treating Constructed Wetlands and Its Potential Usage in a Circular Economy

Researchers identified and characterized microplastics in constructed wetlands used for treating domestic wastewater, finding MP accumulation in the substrate and plants and assessing how well these nature-based treatment systems retain plastic particles before effluent is discharged.

Share this paper