0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Human Health Effects Policy & Risk Sign in to save

Simultaneous quantification of microplastic particles by non-deuterated (NoD) 1H-qNMR from samples comprising different polymer types

The Analyst 2023 12 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count.
Marcel Günther, Wolfgang Imhof

Summary

Researchers developed a non-deuterated proton quantitative NMR method that can simultaneously identify and quantify multiple polymer types in microplastic mixtures, offering a faster and more cost-effective analytical approach.

Facing microplastic contamination and thereby its impacts on the environment and health will probably be one of the most concerning challenges in our immediate future. Yet, data on these emerging pollutants are still scarce in many aspects leading to the ongoing development and expansion of analytical procedures and approaches. In recent years, despite being used formerly only for qualitative aspects, nuclear magnetic resonance spectroscopy (NMR) was introduced for the quantification of microplastic particles. By the combination of linear regression procedures, internal standards and the integration of proton NMR, the so-called qNMR method allows mass-based quantification of microplastics in a limited amount of time and independent of particle size. Based on this approach, further optimization through the simultaneous dissolution and quantification of multiple polymers is investigated. Individual requirements, known issues and considerations will be demonstrated along with additional possibilities for five polymers: polystyrene (PS), butadiene rubber (BR), polyvinylchloride (PVC), polyethylene terephthalate (PET) and polyamide (PA). The applicability of homopolymer-based calibrations is demonstrated for both the quantification of multiple homopolymers dissolved in a shared solvent system and the quantification of copolymers; for example, a styrene-butadiene copolymer (SBR). Linearities and limits of detection and quantification as well as precision and accuracy comparable to those of solely measured microplastic particles are achieved. The improvement significantly reduces the preparation and measurement time in combination with lowered costs. In addition, enhanced reliability was achieved by implementing hexamethyldisiloxane (HMDSO) as an internal standard in NoD measurements, replacing dichloromethane (DCM).

Share this paper