We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
A novel high-throughput analytical method to quantify microplastics in water by flow cytometry
Summary
Researchers developed a faster, high-throughput method using flow cytometry — a technology that rapidly counts and characterizes particles in liquid — to measure microplastics in water, achieving about 97% accuracy across multiple plastic types and sizes and offering a practical alternative to slow, labor-intensive microscopy-based counting.
Microplastics (MPs) are pervasive contaminants with unclear toxicological impacts. Current research on MP pollution relies on low-throughput methodologies, which are time-consuming and cannot directly measure MP concentration in suspensions. This study presents a qualitative and quantitative flow cytometry-based method for analysing MPs in water, offering a faster and more sustainable alternative. The method involves density separation to remove interfering particles, UV irradiation to eliminate microorganisms, and filtration to remove particles above 100 µm. The sensitivity of the method for different types of MPs, such as polystyrene (PS), polypropylene (PP), polyvinyl chloride (PVC), polyethylene terephthalate (PET), and polyamide (PA) microbeads, ranges from 2 µg/L to 1 mg/L. For these MPs, good linearity was found in matrix-matched calibration where the most concentrated standard was 5 mg/L (R2 0.9820–0.9989) although the linear range can be larger (e.g. 42 mg MP/L for PS microbeads). The repeatability and reproducibility of the method for the model PS MP were <17.0% and 8.5%, respectively. The sample treatment method consisting of density separation and UV pretreatment, when carried out independently, led to 95.0% and 93.4% recoveries. The overall trueness of the optimized method for various sizes and compositions of microbeads is about 97%, according to validation supported by microscopy analysis. This method can substitute the traditional quantitative analytical approach based on counting microbeads with microscopy.
Sign in to start a discussion.
More Papers Like This
Flow Cytometry as a Rapid Alternative to Quantify Small Microplastics in Environmental Water Samples
Researchers developed a flow cytometry method using fluorescent staining to rapidly detect and quantify small microplastics (1-50 micrometers) in environmental water samples, achieving over 80% recovery rates and significantly reducing analysis time compared to traditional microscopy.
Can flow cytometry emerge as a high-throughput technique for micro- and nanoplastics analysis in complex environmental aqueous matrices?
Researchers reviewed the potential of flow cytometry — a technique that rapidly analyzes individual particles — as a high-throughput tool for detecting micro- and nanoplastics in water samples, finding it excels at measuring particles smaller than 20 micrometers that other methods struggle to detect. Using fluorescent dyes to tag plastics, the approach could enable near-real-time environmental monitoring at a scale no other current technique can match.
Quantitively Analyzing the Variation of Micrometer-Sized Microplastic during Water Treatment with the Flow Cytometry-Fluorescent Beads Method
Researchers developed a flow cytometry-fluorescent bead method for quantitatively measuring the removal of micrometer-sized microplastics during water treatment processes, demonstrating a rapid and reliable analytical approach for evaluating treatment plant efficiency.
Flow cytometry as new promising detection tool for micro and submicron plastic particles
Researchers evaluated flow cytometry as a detection tool for micro- and nanoplastics, testing its ability to rapidly identify and count plastic particles in environmental and biological samples. Results demonstrated that flow cytometry offers a promising high-throughput approach for microplastic detection compared to more time-intensive conventional methods.
Preliminary Results From Detection of Microplastics in Liquid Samples Using Flow Cytometry
Researchers developed a novel flow cytometry approach for in-situ detection and quantification of microplastics in liquid samples using fluorescent staining, testing nine polymer types under controlled laboratory conditions. The method offers a high-throughput alternative to traditional time-consuming microplastic detection protocols that risk sample contamination.