0
Article Tier 2 Detection Methods Sign in to save

Inter-equipment reliable identification of microplastics by micro-FTIR using low computational resources

AI summary Read the abstract

Researchers developed a low-computational-resource method for reliable microplastic identification by micro-FTIR spectroscopy that performs consistently across different instruments. The approach, funded under the EU PlasticTrace metrology project, addresses inter-equipment variability — a major barrier to harmonized microplastic monitoring — enabling more comparable results across laboratories.

This research is funded by the project 21GRD07 PlasticTrace. This project has received funding from the European Partnership on Metrology, co-financed from the European Union’s Horizon Europe Research and Innovation Programme and by the Participating States. Funder name: European Partnership on Metrology• Funder ID: 10.13039/100019599• Grant number: 21GRD07 PlasticTrace

More Papers Like This

Article Tier 2

Inter-equipment reliable identification of microplastics by micro-FTIR using low computational resources

AI summary Read the abstract

Researchers developed a low-computational-resource method for reliable microplastic identification by micro-FTIR spectroscopy that performs consistently across different instruments. The approach, funded under the EU PlasticTrace metrology project, addresses inter-equipment variability — a major barrier to harmonized microplastic monitoring — enabling more comparable results across laboratories.

Article Tier 2

Toward the Systematic Identification of Microplastics in the Environment: Evaluation of a New Independent Software Tool (siMPle) for Spectroscopic Analysis

AI summary Read the abstract

A new free software tool called siMPle was developed to standardize microplastic identification from FTIR spectroscopy across instruments from different manufacturers, using a shared database and automated analysis pipeline. Testing across four different instrument types confirmed the tool produces consistent and comparable results, addressing a major bottleneck in microplastics monitoring.

Article Tier 2

Inter-instrument definition of valid criteria for the automatic identification of microplastics by micro-Raman spectroscopy

AI summary Read the abstract

Researchers developed a standardized methodology for automatically identifying microplastics using micro-Raman spectroscopy across different laboratory instruments. They determined optimal match algorithms and threshold values that achieved a 95% true positive rate with minimal false positives, even when spectra were collected on different spectrometers. The study addresses a key barrier to reliable, reproducible microplastic identification in environmental and health research.

Article Tier 2

Implications of method- and instrument-based size detection limits in μFTIR-based microplastic analysis

AI summary Read the abstract

This study quantified how both instrument detection limits and methodological choices in micro-FTIR analysis affect reported microplastic concentrations, finding these factors substantially influence numerical results and urging standardization before cross-study comparisons are made.

Article Tier 2

Standardization of micro-FTIR methods and applicability for the detection and identification of microplastics in environmental matrices

AI summary Read the abstract

Researchers worked to standardize micro-FTIR spectroscopy methods for detecting and identifying microplastics as small as 20 micrometers across different environmental samples. They tested reflection and transmission modes against known polymer standards and validated the approach on real-world water, sediment, and biological samples. The study provides a reproducible methodology that could help make microplastic measurements more consistent and comparable across laboratories.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper