0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Gut & Microbiome Human Health Effects Marine & Wildlife Remediation Sign in to save

Performance of a Pilot-Scale Continuous Flow Ozone-Based Hospital Wastewater Treatment System

Antibiotics 2023 11 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Takashi Azuma, Miwa Katagiri, N Sasaki, Makoto Kuroda, Manabu Watanabe

Summary

Researchers evaluated a pilot-scale continuous flow ozone-based treatment system for hospital wastewater and found it effective at reducing antimicrobial resistance markers, offering a practical approach to treating medical facility effluent.

Study Type Environmental

Antimicrobial resistance (AMR) is becoming a global concern. Recently, research has emerged to evaluate the human and environmental health implications of wastewater from medical facilities and to identify acceptable wastewater treatment methods. In this study, a disinfection wastewater treatment system using an ozone-based continuous flow system was installed in a general hospital located in Japan. The effectiveness of antimicrobial-resistant bacteria (ARB) and antimicrobials in mitigating the environmental impact of hospital wastewater was evaluated. Metagenomic analysis was conducted to characterize the microorganisms in the wastewater before and after treatment. The results demonstrated that ozone treatment enables effective inactivation of general gut bacteria, including Bacteroides, Prevotella, Escherichia coli, Klebsiella, DNA molecules, and ARGs, as well as antimicrobials. Azithromycin and doxycycline removal rates were >99% immediately after treatment, and levofloxacin and vancomycin removal rates remained between 90% and 97% for approximately one month. Clarithromycin was more readily removed than the other antimicrobials (81-91%), and no clear removal trend was observed for ampicillin. Our findings provide a better understanding of the environmental management of hospital wastewater and enhance the effectiveness of disinfection wastewater treatment systems at medical facilities for mitigating the discharge of pollutants into aquatic environments.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Pharmaceuticals Removal by Ozone and Electro-Oxidation in Combination with Biological Treatment

Researchers tested the combined use of ozonation and electrochemical oxidation for removing pharmaceutical contaminants from hospital wastewater. They found that the simultaneous application of both methods, following initial biological treatment, achieved complete degradation of refractory compounds and produced a non-toxic effluent. The study suggests this combined approach is a promising solution for treating pharmaceutical-contaminated wastewater from healthcare facilities.

Article Tier 2

Estudo da degradação de microplásticos em água e efluente secundário de estação de tratamento de esgoto por processos baseados em ozônio

This Brazilian study tested ozone-based water treatment processes for degrading polyethylene microplastics in both clean water and secondary wastewater effluent. While ozonation could break down microplastics into smaller fragments and dissolved organic carbon, it did not fully eliminate them, suggesting the need for combined treatment approaches.

Article Tier 2

The Fate and Occurrence of Antibiotic-Resistant Bacteria and Antibiotic Resistance Genes during Advanced Wastewater Treatment and Disinfection: A Review

This review examines how advanced wastewater treatment and disinfection methods perform at removing antibiotic-resistant bacteria and their resistance genes. While methods like UV, ozone, and membrane filtration reduce resistance levels, none fully eliminate them, and some treatments can even promote gene transfer. Since wastewater plants are key nodes where antibiotic resistance spreads to the environment, improving these treatment processes is critical for public health.

Article Tier 2

Insights into the removal of gaseous oxytetracycline by combined ozone and membrane biofilm reactor

Researchers developed a combined ozone and membrane biofilm reactor system for treating gaseous oxytetracycline emitted from livestock manure composting, achieving high removal efficiency through synergistic oxidation and biodegradation mechanisms.

Article Tier 2

Ozonation and its Application in Wastewater Treatment

Not relevant to microplastics — this review covers ozonation and catalytic ozonation as wastewater disinfection and organic pollutant degradation technologies, with no focus on microplastic contamination.

Share this paper