Pharmaceuticals Removal by Ozone and Electro-Oxidation in Combination with Biological Treatment
Summary
Researchers tested the combined use of ozonation and electrochemical oxidation for removing pharmaceutical contaminants from hospital wastewater. They found that the simultaneous application of both methods, following initial biological treatment, achieved complete degradation of refractory compounds and produced a non-toxic effluent. The study suggests this combined approach is a promising solution for treating pharmaceutical-contaminated wastewater from healthcare facilities.
This study investigated the efficiency of two advanced oxidation processes (AOPs), ozonation (O3), and electrochemical oxidation (EO), applied individually or in combination, in the removal of contaminants of emerging concern (CECs) contained in hospital wastewaters, focusing on pharmaceuticals. The optimisation of the single technologies was performed using synthetic wastewater composed of four refractory pharmaceuticals, (carbamazepine-CBZ, lorazepam-LZP, ketoprofen-KTP, 10,11-epoxicarbamazepine-E-CBZ), first alone and then in mixture, in an initial concentration of 1 mg L−1 each. Once the best operational conditions for EO and O3 were defined, their combination (both simultaneous and sequential) was evaluated for the mixture of the selected pharmaceuticals. The treatment solution that showed the best performance was the simultaneous combination of O3 and EO. This treatment was validated using real hospital wastewater previously treated through a moving bed biofilm reactor (MBBR), evaluating its viability by testing the toxicity of the final effluent via Vibrio fischeri inhibition tests. The obtained results showed that the simultaneous combination of O3 and EO as the polishing step after a biological treatment is a very promising solution for hospital wastewater treatment, allowing for obtaining a non-toxic effluent and full degradation of refractory compounds. The disinfection potential of the proposed AOP was also assessed by determining Escherichia coli inactivation potential.
Sign in to start a discussion.
More Papers Like This
Performance of a Pilot-Scale Continuous Flow Ozone-Based Hospital Wastewater Treatment System
Researchers evaluated a pilot-scale continuous flow ozone-based treatment system for hospital wastewater and found it effective at reducing antimicrobial resistance markers, offering a practical approach to treating medical facility effluent.
Assessment of carbamazepine removal from hospital wastewater in a non conventional biofilter and the application of electro-oxidation as pre-treatment
Researchers evaluated a non-conventional biofilter packed with wood chips and porous rock for removing carbamazepine from hospital wastewater, and tested electrochemical oxidation as a pre-treatment step. The biofilter achieved 17.2% biotransformation of carbamazepine at steady state; adding electro-oxidation as pre-treatment increased total removal efficiency to 55%, while organic matter and ammonia removal were unaffected by high drug concentrations.
Critical assessment of advanced oxidation processes and bio-electrochemical integrated systems for removing emerging contaminants from wastewater
This review assesses advanced oxidation processes and bioelectrochemical systems for removing emerging contaminants such as personal care products, antibiotics, and endocrine-disrupting chemicals from wastewater. The study evaluates integrated treatment approaches for addressing these difficult-to-remove pollutants.
Advanced methods for treating gemfibrozil and carbamazepine in wastewater: a review
Researchers reviewed advanced methods for removing two common pharmaceutical pollutants — gemfibrozil (a cholesterol drug) and carbamazepine (an epilepsy drug) — from wastewater, finding that engineered nanomaterials capable of generating highly reactive oxygen radicals can achieve near-complete removal within minutes. These advanced oxidation approaches represent a significant improvement over conventional wastewater treatment, which struggles to break down pharmaceutical contaminants.
Removal of favipiravir and oseltamivir in domestic wastewater effluents using ozonation and catalytic ozonation