0
Article Tier 2 Sign in to save

Paving the way for new and challenging matrix reference materials—particle suspensions at the core of material processing providing RMs for method development and method validation

Analytical and Bioanalytical Chemistry 2023 7 citations

AI summary Read the abstract

This study is not directly about microplastics — it focuses on the technical challenge of producing homogeneous reference materials (including, as one example, microplastic reference materials) by using continuously stirred particle suspensions during manufacturing, and proposes strategies for coordinating method development with reference material production.

Sufficient homogeneity of the certified parameter(s) over the whole fill series of a matrix reference material (RM) is a fundamental quality criterion. In practice, the heterogeneity of the target parameter is evaluated, whereby a relative value can be calculated of how much the target parameter is varying over the RM-batch. A high degree of homogeneity (low heterogeneity) is an inherent quality mark of a good RM. Here, we report how challenging matrix RMs were produced by using particle suspensions at the core of the material processing step. The examples of matrix RMs produced span from whole water reference materials for persistent organic pollutants, PM-like atmospheric dust certified for specific ions to microplastic RMs. Most of these RMs were subsequently used in different phases of analytical method development or for method validation. Common to all these matrices is that they cannot be easily mixed, handled, or dosed to prepare larger sample batches. In all cases, a continuously stirred suspension of particles was used during material processing. In general, relative between-bottle heterogeneities from 1.6 to 6% were achieved for the target parameters in these matrix presentations. Concerning developments of new CRMs in emerging fields, the co-dependence between the availability of validated analytical methods with good repeatability and testing materials with a known and high homogeneity of the target parameter(s) becomes particularly challenging. This situation is an RM/Method causality dilemma. To overcome that hurdle, strategies are proposed for stepwise processes where RM producers and a network of analytical method developers could work hand in hand. In addition, development of a portfolio of inexpensive and well-homogenised common samples coupled with a reporting interface is suggested. This would benefit method developers and RM producers alike. As more and more data is compiled for a specific matrix, it paves the way for new and challenging RMs that can later be used by a wider community.

More Papers Like This

Article Tier 2

A novel proof of concept approach towards generating reference microplastic particles

AI summary Read the abstract

Researchers developed a new method for creating standardized reference microplastic particles that can be embedded in a dissolvable matrix in precise, known quantities. Current microplastic research suffers from a lack of consistent reference standards, making it difficult to compare results across different laboratories and methods. The approach could significantly improve the quality and comparability of microplastic measurements in environmental studies.

Article Tier 2

A novel proof of concept approach towards generating reference microplastic particles

AI summary Read the abstract

This paper presented a proof-of-concept approach for generating standardized reference microplastic particles to improve comparability across analytical methods. The lack of consistent reference materials has been a key barrier to producing reliable and comparable microplastic research data.

Article Tier 2

Production, labeling, and applications of micro- and nanoplastic reference and test materials

AI summary Read the abstract

This study reviews methods for producing, labeling, and applying micro- and nanoplastic reference and test materials for research purposes. The researchers address the growing need for in-house production of standardized test materials, driven by challenges in extracting these particles from the environment and the limited range of commercially available options.

Article Tier 2

Preparation of a reference material for microplastics in water—evaluation of homogeneity

AI summary Read the abstract

Researchers developed a candidate reference material for microplastics in water and evaluated its homogeneity, finding it suitable for use in laboratory intercomparison studies and as a tool for validating microplastic analytical methods.

Article Tier 2

Standard Practice for Development of Microplastic Reference Samples for Calibration and Proficiency Evaluation in All Types of Water Matrices with High to Low Levels of Suspended Solids

AI summary Read the abstract

This ASTM standard practice provides procedures for creating reference microplastic particle samples for use in calibrating and evaluating microplastic detection methods. Standardized reference materials are essential for ensuring that different laboratories produce consistent and comparable microplastic measurement results.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper