0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Remediation Sign in to save

Microplastics fouling mitigation in forward osmosis membranes by the molecular assembly of sulfobetaine zwitterion

Desalination 2024 24 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count.
Javad Farahbakhsh, Mitra Golgoli, Mehdi Khiadani, Amir Razmjou, Masoumeh Zargar

Summary

Scientists developed a new water-filtering membrane coated with a special molecule that resists clogging from microplastics, which are increasingly showing up in our drinking water and have been linked to potential health concerns. The upgraded membrane not only filtered water more efficiently but could be cleaned and restored to over 90% effectiveness in just 30 minutes, making it a promising step toward more affordable, low-maintenance systems for removing microplastics from water supplies.

Forward osmosis (FO) membranes have potential for the efficient water and wastewater treatment applications. However, their development has faced significant challenges due to their fouling propensity. In this study, FO membranes modified with sulfobetaine zwitterions (i.e., [2-(Methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl) ammonium hydroxide) were fabricated and used for the first time to address microplastic (MP) fouling issue. Water flux, reverse salt flux (RSF), fouling, and flux recovery were evaluated for the membranes loaded with different quantities of the zwitterions ranging from 0.25 % to 2 %. The developed membranes were tested over 49 h with feed solutions containing polyethylene MPs and bovine serum albumin (BSA) to evaluate their fouling resistance. The synergistic effects of the two foulants indicated that the MPs were the primary cause of fouling. The presence of BSA effectively reduced the blocking effect of MPs and therefore lowers overall fouling. Additionally, improved water flux, structural parameter (S), and RSF were reported for the modified membranes. The zwitterion's unique structure with hydrophilic groups (CO and OSO) resulted in high flux recovery rates of over 90 % for all modified membranes within only 30 min of physical cleaning upon fouling tests. The results demonstrate the high potential of the modification method for targeting the removal of MPs in TFC-based membranes.

Share this paper