0
Article Tier 2 Detection Methods Gut & Microbiome Human Health Effects Remediation Reproductive & Development Sign in to save

A Robust Multistep Digestion Method for Microplastics Detection in Human Tissue by MicroRaman Analysis

AI summary Read the abstract

Researchers developed and optimized a robust three-day digestion protocol for extracting microplastics from nine types of human tissue, including brain, lung, liver, and placenta. The method combined Fenton oxidation, enzymatic digestion with proteinase K, and lipid removal through ethanol sonication, achieving clear filtrates while preserving common polymer types. The protocol enabled successful microplastic detection at the 1-micrometer scale using micro-Raman spectroscopy across all tested tissue types.

The presence of microplastics (MPs) in human tissues has raised growing concerns, necessitating robust protocols for their reliable extraction and analysis. This study systematically evaluated and optimized digestion protocols to efficiently process a variety of human tissues-placenta, lung, kidney, adipose tissue, muscle, spleen, liver, thyroid, and brain-while preserving the integrity of MP particles. Initial assessments employing single-reagent protocols such as nitric acid (HNO3), proteinase K enzymatic digestion, and Fenton oxidative digestion demonstrated limited effectiveness, due to incomplete tissue breakdown or formation of turbid digestates that hindered filtration. Building upon these results, combined digestion approaches were investigated to improve organic matter removal and facilitate filtration through fine pore-size filters (0.2 μm). The optimized 3-day protocol included an initial oxidative Fenton digestion followed by enzymatic digestion (proteinase K). The final step involved lipid removal through ethanol addition and sonication, resulting in clear digestates amenable to filtration. This protocol efficiently digested complex tissue matrices, reducing filter clogging at 1-μm size pore and preserving various common MP polymers, including low-density polyethylene (LDPE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyamides (PA6 and PA12). Application of the optimized digestion allowed successful isolation and characterization of MPs using optical microscopy and Raman spectroscopy. The method showed improved reproducibility and reliability over single-reagent protocols, making it suitable for comprehensive MP analysis in human tissues. The application of an efficient and robust protocol for tissue digestion may contribute to advance human exposure assessment and toxicological studies related to MP contamination.

More Papers Like This

Article Tier 2

Sample Preparation Protocol for the Extraction and Raman analysis of Small Microplastics in Infant Milk Formula

AI summary Read the abstract

Researchers published a standard operating procedure for extracting microplastics from infant milk formula using optimized chemical digestion steps to remove proteins, fats, and carbohydrates while preserving microplastic integrity for subsequent µ-Raman spectroscopy identification.

Article Tier 2

Sample Preparation Protocol for the Extraction and Raman analysis of Small Microplastics in Infant Milk Formula

AI summary Read the abstract

Researchers developed a standardized sample preparation protocol for extracting and characterizing microplastics (1-1000 µm) from infant milk formula using chemical digestion to remove complex organic matrix components while preserving particle integrity for µ-Raman spectroscopy analysis.

Article Tier 2

A simple and reliable method for the qualitative and quantitative analysis of nano- and microplastics in organs for controlled preclinical studies

AI summary Read the abstract

Researchers developed a non-destructive method for recovering and quantifying microplastics from organ tissues using proteinase K digestion followed by UV-Vis spectrophotometry, achieving over 90% accuracy across nine polymer types and preserving particle integrity for downstream physicochemical analysis — a key advantage over acid or alkali digestion methods.

Article Tier 2

Validation of an extraction method for microplastics from human materials

AI summary Read the abstract

Researchers validated an extraction method for isolating microplastics from human and animal tissues, confirming that the procedure does not cause significant alteration to the plastic particles themselves.

Article Tier 2

Methods for the detection of microplastics in mammals

AI summary Read the abstract

Scientists now detect microplastics in human blood, lungs, placentas, and other tissues, but the field still lacks a single gold-standard method for measuring them. This review compares the strengths and limitations of current detection techniques — including spectroscopy, microscopy, and chemical digestion — to help standardize how microplastics in the human body are quantified, which is a prerequisite for accurately assessing health risks.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper