0
Article Tier 2 Detection Methods Nanoplastics Policy & Risk Remediation Sign in to save

Quantification of Nanoplastics and Inorganic Nanoparticles via Laser‐Induced Breakdown Detection (LIBD)

AI summary Read the abstract

Researchers examined the sensitivity of laser-induced breakdown detection (LIBD) for quantifying nanoplastics and inorganic nanoparticles in water, finding detection limits of 10^4 to 10^5 particles per millilitre for polystyrene, polypropylene, and PET nanoplastics — one to two orders of magnitude lower than competing methods — making LIBD a robust candidate for membrane integrity monitoring and water treatment assessment.

Nanoparticles with diverse characteristics are difficult to quantify at low concentrations in the water environment (10$^6$–10$^9$ particles mL$^{−1}$ for nanoplastics originating from the breakdown of plastic debris) for the evaluation of effective treatment methods. This study examines the sensitivity, or limit of detection (LOD), of laser-induced breakdown detection (LIBD) for the counting of nanoparticles, including nanoplastics. For polystyrene (PS) standards with sizes of 20−400 nm, LIBD shows relatively low LODs (for example, 2 × 10$^6$ particles mL$^{−1}$ for 100 nm particles) compared with turbidity monitoring, UV–vis spectroscopy (both 6 × 10$^8$ particles mL$^{−1}$), and nanoparticle tracking analysis (2 × 10$^7$ particles mL$^{−1}$). For nanoplastics (PS, polypropylene, and polyethylene terephthalate), the detection limits are 10$^4$ − 10$^5$ particles mL$^{−1}$, one to two orders of magnitude lower than the PS standards. LIBD can quantify inorganic nanoparticles, such as zeolite, titania, and hematite. The sensitivity increases (i.e., LOD reduces) with increasing particle density, while some particles are prone to artifacts. The low LODs make LIBD a robust technique for counting nanoparticles of various types and sizes, even at the concentrations found in the permeate of membrane-based water treatment systems. Given the high sensitivity, LIBD has the potential to be applied in membrane integrity monitoring and fundamental studies on membrane mechanisms.

More Papers Like This

Article Tier 2

Quantification of Nanoplastics and Inorganic Nanoparticles via Laser‐Induced Breakdown Detection (LIBD)

AI summary Read the abstract

Researchers developed a laser-induced breakdown spectroscopy (LIBS) method for quantifying nanoplastics and distinguishing them from inorganic nanoparticles in environmental samples, demonstrating detection limits and specificity suitable for routine environmental monitoring.

Article Tier 2

Real-time quantification of nanoplastics deposition in nanofiltration using laser-induced breakdown detection (LIBD)

AI summary Read the abstract

Scientists tested how well water filtration membranes trap tiny plastic particles (nanoplastics) and found that at higher water flow rates, these membranes can capture up to 100% of the particles—but the plastic often sticks to the filter and doesn't fully wash away during cleaning. This matters because as we look for ways to remove nanoplastics from drinking water, understanding how these filters actually perform (and how they might get "clogged" with trapped plastic over time) helps engineers design better water treatment systems to keep this emerging pollutant out of what we drink.

Article Tier 2

Real-time quantification of nanoplastics deposition in nanofiltration using laser-induced breakdown detection (LIBD)

AI summary Read the abstract

Water filters designed to remove nanoplastics (tiny plastic particles too small to see) can actually get clogged with the very particles they're supposed to block, and simple backwashing doesn't always fully clean them out. Using a new laser-based detection tool, researchers found that how fast water flows through the filter determines whether these plastic particles stick around or wash away—information that could help engineers design better water treatment systems to keep nanoplastics out of our drinking water. This matters because as concerns grow about nanoplastics accumulating in our bodies, having filtration systems that reliably remove them is an important piece of protecting public health.

Article Tier 2

Fiber Laser-Backscattered Optofluidic Sensor for Ultrasensitive and Wide-Range Nanoplastic Quantification

AI summary Read the abstract

Scientists have developed a new laser-based sensor that can detect and measure tiny plastic particles called nanoplastics in water, even at extremely low concentrations. This matters because nanoplastics are too small to see and hard to detect with current tools, but they may end up in our drinking water and food—this device could enable faster, on-site testing to monitor contamination levels. While the tool shows promise in real water samples, more research is needed to understand what levels of nanoplastic exposure actually mean for human health.

Article Tier 2

Fiber Laser-Backscattered Optofluidic Sensor for Ultrasensitive and Wide-Range Nanoplastic Quantification

AI summary Read the abstract

Scientists have built a laser-based sensor that can detect and measure incredibly tiny plastic particles—called nanoplastics—in water, even at very low concentrations and across a wide range of sizes. This matters because nanoplastics are showing up everywhere, including in drinking water and our bodies, but they've been hard to detect and measure accurately; this new tool could make it easier to monitor plastic pollution in real time and better understand our actual exposure to it.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper