0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Sign in to save

Measurement of the Effective Refractive Index of Suspensions Containing 5 µm Diameter Spherical Polystyrene Microparticles by Surface Plasmon Resonance and Scattering

Chemosensors 2025 Score: 48 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Osvaldo Rodríguez-Quiroz, Donato Luna-Moreno, Araceli Sánchez-Álvarez, Gabriela Elizabeth Quintanilla-Villanueva, Oscar Javier Silva-Hernández, Melissa Marlene Rodríguez-Delgado, Juan Francisco Villarreal-Chiu

Summary

This study used surface plasmon resonance combined with Mie scattering theory to measure the effective refractive index of suspensions containing 5 µm polystyrene microspheres, proposing this approach as a foundation for optical detection methods for microplastics in water.

Polymers

Microplastics (MP) have been found not only in the environment but also in living beings, including humans. As an initial step in MP detection, a method is proposed to measure the effective refractive index of a solution containing 5 µm diameter spherical polystyrene particles (SPSP) in distilled water, based on the surface plasmon resonance (SPR) technique and Mie scattering theory. The reflectances of the samples are obtained with their resonance angles and depths that must be normalized and adjusted according to the reference of the air and the distilled water, to subsequently find their effective refraction index corresponding to the Mie scattering theory. The system has an optical sensor with a Kretschmann–Raether configuration, consisting of a semicircular prism, a thin gold film, and a glass cell for solution samples with different concentrations (0.00, 0.20, 0.05, 0.50, and 1.00%). The experimental result provided a good linear fit with an R2 = 0.9856 and a sensitivity of 7.2863 × 10−5 RIU/% (refractive index unit per percentage of fill fraction). The limits of detection (LOD) and limit of quantification (LOQ) were determined to be 0.001% and 0.0035%, respectively. The developed optomechatronic system and its applications based on the SPR and Scattering enabled the effective measurement of the refractive index and concentration of solutions containing 5 µm diameter SPSP in distilled water.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Measurement of the Effective Refractive Index of Suspensions Containing 5 µm Diameter Spherical Polystyrene Microparticles by Surface Plasmon Resonance and Scattering

Researchers developed a surface plasmon resonance method combined with Mie scattering theory to measure concentrations of 5-micrometer polystyrene microparticles in water. The system achieved good sensitivity with a detection limit of 0.001% concentration and strong linearity, demonstrating a promising optical approach for microplastic detection in aqueous samples.

Article Tier 2

RefractiveIndex of Benchmark Polystyrene Nanoplasticsby Optical Modeling of UV–Vis Spectra

Researchers measured UV-visible spectra of polystyrene nanobeads deposited on sapphire substrates and applied a new optical model based on Mie theory to determine the refractive index of polystyrene nanoplastics below 1 micrometre, bridging a critical gap in the optical characterisation of nanoplastic particles.

Article Tier 2

Measurements of the inherent optical properties of aqueous suspensions of microplastics

Researchers measured the inherent optical properties — including absorption and scattering coefficients — of aqueous microplastic suspensions at environmentally relevant concentrations, comparing different polymer types and particle sizes. The optical signatures varied substantially across polymers and sizes, providing reference data for developing optical remote sensing approaches to detect microplastics in surface waters.

Article Tier 2

Direct Detection of Polystyrene Nanoplastics in Water Using High-sensitivity Surface-enhanced Raman Scattering with Ag Nanoarray Substrates

Researchers developed a fast, sensitive detection method using silver nanostructures and laser light scattering (surface-enhanced Raman scattering) to identify polystyrene nanoplastics in water at concentrations as low as 10 micrograms per milliliter, offering a practical tool for monitoring nanoplastic contamination in real-world water sources.

Article Tier 2

Sensors for Polystyrene Nanoplastics Detection in Water Samples

This review assessed recent advances in sensor and biosensor technologies for detecting polystyrene nanoplastics in complex aquatic samples. The authors identified optical, electrochemical, and surface-enhanced Raman approaches as the most promising strategies, while highlighting the ongoing challenges of matrix interference and low-concentration detection limits.

Share this paper