0
Article Sign in to save

Plastics Recycling: A Comparative Study of Different Analytical Techniques

Journal of Epidemiology and Health Science 2025 1 citation

AI summary Read the abstract

This study compared multiple analytical techniques for identifying and quantifying mixed post-consumer plastic waste, finding that solid-state 13C NMR outperformed conventional near-infrared methods by precisely distinguishing polyolefin types—including different polyethylene subtypes—and accurately quantifying plastics in mixed waste samples.

Polymers

ABSTRACT Plastic waste has become a critical challenge threatening our environment and survival. There has been a growing demand for recycling methods to process waste into clean virgin‐like material. However, one of the key challenges limiting recyclability is the difficulty in accurately identifying different types of plastics in post‐consumer kerbside waste. Commercial sorting of collected waste relies primarily on near infrared technology, which is associated with significant limitations. Herein, we compared a range of analytical techniques to identify different post‐consumer plastic waste samples. With the finding that 13 C solid state NMR can precisely identify different polyolefins, we explored the possibility of employing 13 C solid state NMR for quantification of plastics from mixed waste samples, which can be quite difficult to quantitate using other standard techniques. Our results demonstrate that 13 C solid‐state NMR is highly efficient in the quantification of polyolefins from different controlled mixtures. For identification, DSC and NMR are methods of choice with the most clear differences between different polymers, with the exception of different polyethylene subtypes being more suitable for NMR analysis.

More Papers Like This

Article Tier 2

Applicability of NMR spectroscopy to quantify microplastics across varying concentrations in polymer mixtures

AI summary Read the abstract

Quantitative NMR spectroscopy was evaluated as a method for measuring synthetic polymers in mixed microplastic samples at low concentrations, finding it feasible but constrained by overlapping signals and solvent limitations, offering a cost-efficient alternative to spectroscopic methods for certain polymer mixture analyses.

Article Tier 2

The first application of quantitative 1H NMR spectroscopy as a simple and fast method of identification and quantification of microplastic particles (PE, PET, and PS)

AI summary Read the abstract

Researchers demonstrated that quantitative ¹H NMR spectroscopy (qNMR) can identify and quantify polyethylene, PET, and polystyrene microplastic particles in solution with linearity above R²=0.994 and detection limits in the environmentally relevant range (~19–21 μg/mL), offering a faster size-independent alternative to conventional FTIR and Raman particle counting.

Article Tier 2

Microplastic quantification in environmental samples with complex organic matrices by diffusion NMR

AI summary Read the abstract

Researchers applied diffusion NMR spectroscopy to quantify microplastics in environmental samples with complex organic matrices, demonstrating the technique's capacity to characterize polymer types in difficult real-world sample conditions where existing methods fall short.

Article Tier 2

Overcoming the challenge of quantifying aged microplastic by qNMR spectroscopy

AI summary Read the abstract

Researchers evaluated quantitative nuclear magnetic resonance spectroscopy for analyzing environmentally aged microplastics made of polystyrene, polyvinyl chloride, and polyethylene terephthalate. The study found that UV exposure and elevated temperatures during aging altered the spectral properties of these polymers, and developed approaches to overcome the quantification challenges posed by environmental weathering.

Article Tier 2

Highly selective solid–liquid extraction of microplastic mixtures as a pre-preparation tool for quantitative nuclear magnetic resonance spectroscopy studies

AI summary Read the abstract

Researchers developed a solid-liquid extraction procedure using common laboratory equipment to selectively separate microplastic mixtures from inorganic matrix substances as sample preparation for quantitative NMR spectroscopy. The protocol addresses a key gap preventing qNMR from being applied to real environmental microplastic samples containing diverse polymer mixtures.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper