We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Time-of-flight secondary ion mass spectrometry (ToF-SIMS)-based analysis and imaging of polyethylene microplastics formation during sea surf simulation
AI summary Read the abstract
This study applied time-of-flight secondary ion mass spectrometry (ToF-SIMS) to image and chemically characterize microplastic particles from cosmetic products and environmental samples at high resolution. The technique enables detailed surface chemical analysis of small plastic particles, adding a powerful analytical tool to the microplastic detection toolkit.
Plastic particles smaller than 5mm, so called microplastics have the capability to accumulate in rivers, lakes and the marine environment and therefore have begun to be considered in eco-toxicology and human health risk assessment. Environmental microplastic contaminants may originate from consumer products like body wash, tooth pastes and cosmetic products, but also from degradation of plastic waste; they represent a potential but unpredictable threat to aquatic organisms and possibly also to humans. We investigated exemplarily for polyethylene (PE), the most abundant constituent of microplastic particles in the environment, whether such fragments could be produced from larger pellets (2mm×6mm). So far only few analytical methods exist to identify microplastic particles smaller than 10μm, especially no imaging mass spectrometry technique. We used at first time-of-flight secondary ion mass spectrometry (ToF-SIMS) for analysis and imaging of small PE-microplastic particles directly in the model system Ottawa sand during exposure to sea surf simulation. As a prerequisite, a method for identification of PE was established by identification of characteristic ions for PE out of an analysis of grinded polymer samples. The method was applied onto Ottawa sand in order to investigate the influence of simulated environmental conditions on particle transformation. A severe degradation of the primary PE pellet surface, associated with the transformation of larger particles into smaller ones already after 14days of sea surf simulation, was observed. Within the subsequent period of 14days to 1month of exposure the number of detected smallest-sized particles increased significantly (50%) while the second smallest fraction increased even further to 350%. Results were verified using artificially degraded PE pellets and Ottawa sand.
More Papers Like This
ToF‐SIMS characterization of microplastics in soils
AI summary Read the abstract
Researchers applied time-of-flight secondary ion mass spectrometry (ToF-SIMS) to characterize microplastics in soil samples, demonstrating the technique's ability to identify polymer types and surface chemical properties at high spatial resolution. The study proposes ToF-SIMS as a valuable complementary tool for microplastic detection in terrestrial environments where current analytical methods remain inconsistent.
Mass spectra database of polymers for bismuth-cluster ToF-SIMS
AI summary Read the abstract
This study created a reference database of mass spectra for common commercial polymers using bismuth-cluster time-of-flight secondary ion mass spectrometry (ToF-SIMS). The database fills a critical gap for researchers trying to identify and classify microplastic particles in environmental samples using this high-resolution analytical technique.
Rapid Single Particle Atmospheric Solids Analysis Probe-Mass Spectrometry for Multimodal Analysis of Microplastics
AI summary Read the abstract
Researchers developed an atmospheric solid analysis probe coupled to mass spectrometry for rapid chemical characterization of single microplastic particles, enabling polymer identification while remaining compatible with complementary imaging techniques for comprehensive microplastic analysis.
Visualization and (Semi-)quantification of submicrometer plastics through scanning electron microscopy and time-of-flight secondary ion mass spectrometry
AI summary Read the abstract
Researchers combined scanning electron microscopy and time-of-flight secondary ion mass spectrometry to detect and semi-quantify submicron plastic particles from 195 nm upward, demonstrating the method on teabag leachates and showing it can distinguish multiple polymer types in complex mixtures.
Recent developments in mass spectrometry for the characterization of micro- and nanoscale plastic debris in the environment
AI summary Read the abstract
This review examines advances in mass spectrometry techniques for characterizing micro- and nanoplastic debris in environmental samples, covering particle sizing, polymer identification, and quantification approaches. Improved mass spectrometry methods are expanding the ability to detect and characterize nanoplastics, which are particularly challenging to measure with conventional spectroscopic approaches.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.