We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Automated thermal extraction-desorption gas chromatography mass spectrometry: A multifunctional tool for comprehensive characterization of polymers and their degradation products
AI summary Read the abstract
This paper describes how automated thermal extraction-desorption gas chromatography mass spectrometry (TED-GC-MS) can comprehensively characterize polymer composition and degradation products in environmental samples. The technique offers a promising approach for identifying and quantifying microplastics as well as understanding their chemical transformation in the environment.
The TED-GC-MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC-MS). This method is ideally suited for the analysis of polymers and their degradation processes. Here, a new entirely automated system is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. The fractionated collection together with low temperatures reduces the risk of contamination, improves instrumental stability and minimizes maintenance efforts. Through variation of the two main parameters (purge gas flow and heating rate) it is shown how the extraction process can be optimized. By measuring the decomposition products of polyethylene it is demonstrated that compounds with masses of up to 434 Da can be detected. This is achieved despite the low temperature (˜40 °C) of the solid-phase adsorber and the low thermal desorption temperature of 200 °C in the TDU unit. It is now shown that automated TED-GC-MS represents a new flexible multi-functional method for comprehensive polymer analyses. Comparable polymer characterization was previously only achievable through a combination of multiple independent analytical methods. This is demonstrated by three examples focused on practical challenges in materials analysis and identification: The first one is the analysis of wood plastic composites for which the decomposition processes of the polymer and the bio polymer (wood) could be clearly distinguished by fractionated collection using sequential adsorbers. Secondly, a fast quantitative application is shown by determining the weight concentrations of an unknown polyolefin blend through comparison with a reference material. Additionally, the determination of microplastic concentrations in environmental samples is becoming an increasingly important analytical necessity. It is demonstrated that with TED-GC-MS calibration curves showing good linearity for the most important precursors for microplastic, even complex matrix materials (suspended particulate matter) can be successfully analyzed.
More Papers Like This
Thermal extraction/desorption-gas chromatography-mass spectroscopy: A powerful tool for analyzing the degradation and decomposition of polymers
AI summary Read the abstract
This paper describes thermal extraction/desorption-gas chromatography-mass spectrometry as a powerful analytical tool for characterizing plastic polymers by analyzing their thermal degradation products, with applications for identifying microplastic types in environmental samples.
Accelerated Determination of Microplastics in Environmental Samples Using Thermal Extraction Desorption-Gas Chromatography/Mass Spectrometry (TED-GC/MS)
AI summary Read the abstract
This application note describes a thermal extraction desorption gas chromatography/mass spectrometry (TED-GC/MS) method for rapidly quantifying microplastics in environmental samples. The method handles larger sample sizes, detects all particle sizes above the detection limit, and is well-suited to automation for higher throughput environmental monitoring.
Determination of microplastic mass content by thermal extraction desorption gas chromatography-mass spectrometry
AI summary Read the abstract
Researchers validated thermal extraction desorption gas chromatography-mass spectrometry (TED-GC-MS) as a rapid method for measuring the mass of microplastics in environmental samples. The technique can identify and quantify most common thermoplastic polymers in a single run, offering a faster alternative to labour-intensive visual counting methods.
Analysis of microplastics in environmental samples using TED-GC-MS
AI summary Read the abstract
This study evaluated thermal extraction-desorption gas chromatography mass spectrometry (TED-GC-MS) for analyzing microplastic polymer types and additives in environmental samples from rivers, lakes, and biota. The technique enables quantitative polymer identification and can simultaneously detect plastic additives, offering advantages over spectroscopy-only approaches for comprehensive microplastic characterization.
Analysis of polyethylene microplastics in environmental samples, using a thermal decomposition method
AI summary Read the abstract
Researchers developed a thermal analysis method using pyrolysis-GC/MS to identify and quantify polyethylene microplastics in environmental samples without relying on visual sorting or density separation. The approach provides a more objective and automatable way to measure microplastic mass in complex environmental matrices.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.