Development of methods for extraction and analytical characterization of carbon-based nanomaterials (nanoplastics and carbon nanotubes) in biological and environmental matrices by asymmetrical flow field-flow fractionation
AI summary Read the abstract
Researchers developed asymmetrical flow field-flow fractionation (AF4) methods to extract and size-characterize nanoplastics and carbon nanotubes in biological and environmental matrices, finding the approach successfully fractioned nanoplastics coated with natural organic matter but failed to efficiently recover carbon nanotubes from eggshell matrices.
Suitable methods and fit-for-purpose techniques are required to allow characterization of carbon-based nanomaterials (CB-NMs) in complex matrices. In this study, two methods were developed; a method for extraction and characterization of CB-NMs in biological media and a method for fractionation of natural organic matter (NOM) coated CB-NMs in environmental matrices. The former method was developed by extracting carbon nanotubes (CNTs: sized 0.75 × 3000 nm) and nanoplastics (sized 60, 200 and 600 nm) from eggshells and characterizing the extracted CB-NMs in terms of particle size distribution using asymmetrical flow field-flow fractionation (AF4) coupled with multi-angle light scattering (MALS). The latter method was developed using AF4-MALS to fraction NOM-coated CNT (sized 0.75 × 3000 nm) and nanoplastics (sized 60, 200 and 300 nm) in a simulated natural surface water and provide information about the size distribution of the CB-NM-NOM complexes. The developed AF4-MALS method successfully fractioned the CB-NM-NOM complexes based on hydrodynamic size and provided the size distribution of the complexes. The NOM corona did not shift significantly the median size of the CB-NMs. It influenced however the size distribution of the nanoplastics and CNTs. The sample preparation method failed to extract the CNTs (recovery < 20%) from the matrices of the eggshells while being successful for extracting the nanoplastics (recoveries > 60%). The AF4-MALS fractogram showed that the extraction method did not significantly influence the size distribution of the nanoplastics of 60 and 200 nm size, whereas the peak of 600 nm nanoplastics shifted towards a smaller hydrodynamic size. In conclusion, the developed sample preparation method followed by the developed AF4-MALS method can be applied for extraction, separation and characterization of CB-NMs in biological and environmental matrices. Thus, the methods have a high potential to be methods of choice to investigate CB-NMs in future studies.
More Papers Like This
Selective quantification of nanoplastics in environmental matrices by asymmetric flow field-flow fractionation with total organic carbon detection
AI summary Read the abstract
Researchers developed the first proof-of-principle method hyphenating asymmetric flow field-flow fractionation (AF4) with total organic carbon detection for selective quantification of nanoplastics in environmental matrices, demonstrating improved robustness against dissolved organic matter and clay colloid interference compared to existing approaches.
A method for efficient separation of polystyrene nanoplastics and its application in natural freshwater
AI summary Read the abstract
Researchers developed a method using asymmetrical flow field-flow fractionation (AF4) coupled with multiple detectors to efficiently separate and characterize polystyrene nanoplastics by particle size in freshwater environments, demonstrating its applicability for analysing nanoplastic environmental behaviour in natural freshwater samples.
Asymmetrical flow field flow fractionation methods to characterize submicron particles: application to carbon-based aggregates and nanoplastics
AI summary Read the abstract
Researchers developed and validated an asymmetrical flow field-flow fractionation (AF4) strategy capable of rapidly sizing and separating submicron particles — including nanoplastics — across the full colloidal range from 10 to 800 nm using a single programmed method with four high-resolution sub-fractionation windows.
Matrix OverloadingEffects on Size-Resolved Quantificationof Low-Concentration Nanoplastics in Complex Environmental MatricesUsing Asymmetric Flow Field-Flow Fractionation
AI summary Read the abstract
Researchers developed a size-resolved nanoplastic quantification method using asymmetric flow field-flow fractionation with on-channel preconcentration, identifying and characterizing matrix overloading effects that cause analytical artifacts when measuring nanoplastics in complex environmental water samples.
Matrix Overloading Effects on Size-Resolved Quantification of Low-Concentration Nanoplastics in Complex Environmental Matrices Using Asymmetric Flow Field-Flow Fractionation
AI summary Read the abstract
Researchers developed a size-resolved method for quantifying nanoplastics in the 20-200 nm range in environmental water samples using asymmetric flow field-flow fractionation. The study identified important analytical artifacts from matrix overloading effects that can occur when measuring low-concentration nanoplastics in complex environmental samples, providing guidance for more accurate quantification methods.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.