0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Sign in to save

Detection of trace sub-micron (nano) plastics in water samples using pyrolysis-gas chromatography time of flight mass spectrometry (PY-GCToF).

Chemosphere 2020 159 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 45 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
G.L. Sullivan, Javier Delgado Gallardo, Eurig W. Jones, P.J. Hollliman, Trystan Watson, S. Sarp

Summary

Researchers evaluated pyrolysis-gas chromatography/mass spectrometry combined with thermal extraction-desorption for detecting sub-micron and nano-sized plastics in water samples, finding it could identify plastic polymers at low concentrations. The method addresses a key gap in detecting the smallest plastic particles in aqueous environments.

Study Type Environmental

The identification and quantification of micro and nanoplastics (MPs and NPs respectively) requires the development of standardised analytical methods. Thermal analysis methods are generally not considered a method of choice for MPs analysis, especially in aqueous samples due to limited sample size introduction to the instrument, decreasing the detection levels. In this article, pyrolysis - Gas chromatography time of flight mass spectrometry (Py-GCToF) is used as a method of choice for detection of MPs and NPs due to its unprecedented detection capabilities, in combination with PTFE membranes as sample support, allow for smaller particle sizes (>0.1 μm) in water samples to be identified. The utilisation of these widely used membranes and the identification of several and specific (marker) ions for the three plastics in study (polypropylene (PP), polystyrene (PS) and polyvinyl chloride (PVC)), allows for the extraction of individual plastics from complex signals at trace levels. The method was validated against a number of standards, containing known quantities of MPs. Detection levels were then determined for PVC and PS and were found to be below <50 μg/L, with repeatable data showing good precision (%RSD <20%). Further verification of this new method was achieved by the analysis of a complex sample, sourced from a river. The results were positive for the presence of PS with a semi-quantifiable result of 241.8 μg/L. Therefore PY-GCToF seems to be a fit for purpose method for the identification of MPs and NPs from complex mixtures and matrices which have been deposited on PTFE membranes.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Identification and Quantification of Nanoplastics in Surface Water and Groundwater by Pyrolysis Gas Chromatography–Mass Spectrometry

Researchers developed a method combining ultrafiltration and pyrolysis gas chromatography-mass spectrometry to identify and quantify nanoplastics in surface water and groundwater. The study successfully detected six types of plastic polymers at the nanoscale in environmental water samples, providing much-needed quantitative data on nanoplastic pollution in real-world water sources.

Article Tier 2

Cloud-Point Extraction Combined with Thermal Degradation for Nanoplastic Analysis Using Pyrolysis Gas Chromatography–Mass Spectrometry

Researchers developed a cloud-point extraction method combined with pyrolysis GC-MS to detect and quantify nanoplastics in aqueous samples, achieving detection of particles smaller than those typically measurable with conventional microplastic methods. The technique addresses a critical analytical gap in understanding nanoplastic contamination in water environments.

Article Tier 2

Identification of Microplastics in Drinking Water Using Pyrolysis-GC/MS

Researchers used pyrolysis-GC/MS to identify and quantify microplastics by polymer mass (rather than particle count) in drinking water samples. The method detected multiple polymer types and provided mass-based metrics that are more toxicologically relevant than particle counts commonly reported in water quality studies.

Article Tier 2

Optimization, performance, and application of a pyrolysis-GC/MS method for the identification of microplastics

Researchers optimized a pyrolysis-GC/MS method for identifying and quantifying microplastics in environmental samples, improving the reliability of polymer identification especially for small particles that are difficult to classify visually. The improved method is particularly valuable for analyzing the smallest microplastic size fractions that dominate by number in marine environments.

Article Tier 2

Simultaneous Trace Identification and Quantification of Common Types of Microplastics in Environmental Samples by Pyrolysis-Gas Chromatography–Mass Spectrometry

Researchers developed a method for simultaneous trace identification and quantification of common microplastic types in environmental samples, improving detection efficiency and enabling more accurate monitoring of multiple plastic polymers at once.

Share this paper