0
Article Tier 2 Environmental Sources Gut & Microbiome Marine & Wildlife Policy & Risk Remediation Sign in to save

Results of the evaluation of the semi-empirical model on the selection of optimal constructive and technological parameters for a granulated loading filter

AI summary Read the abstract

This engineering study evaluated a semi-empirical model for optimizing the design parameters of a granulated filter used in water treatment at a food processing facility. Researchers found that mechanical filtration could effectively reduce colloidal phytoplankton contamination in process water. This is a water treatment engineering study with limited direct relevance to microplastic research.

Polymers
Study Type Environmental

Topicality. A survey of the water use system at a state-owned enterprise processing agricultural products revealed the technological processes that cause biofouling of pipelines by colloidal inclusions (mainly phytoplankton conglomerates of blue-green algae). The implementation of measures that can protect existing technological structures against the ingress of significant masses of phytoplankton is an urgent task that can be solved with the help of mechanical filters. The efficiency of previous granulated loading filters depends very much on the properties of the filter loading. When filter loading is made of foamed polystyrene granules of food brands, phytoplankton retention is quite effective due to the physical adsorption of cyanobacteria conglomerates on the surface of these granules. Research results. By applying the semi-empirical model developed in IWPLR of NAAS, the optimal design and technological parameters of the filter with foam polystyrene loading were selected. That enabled to develop the design of a clarifying filter - a phytoplankton retainer for the treatment of circulating water at the enterprise Chervonoslobidsky distillery. In the lower part of the filter the lower drainage system in the form of a false bottom is placed, equipped with hole caps. It provides the source water entry for filtration and discharge of flush water during filter washing. The granules of the filter loading are kept from floating with the false bottom of the upper drainage, which is equipped with return filters - hole caps. Filtered water is collected in the abovefiltering space between the false bottom and the upper part of the filter body, from where it is delivered through a pipeline to the consumers. The application of the developed filter design allows reducing the construction costs and simplifies the filter design, which in turn increases its reliability and overall service life. The practical application of this filter provided the required degree of retention of cyanobacteria cells and conglomerates from the treated water. This filter design differs from the standard with a 1.5 times increased filter loading layer. This enabled to double the duration of a filter cycle and, at the same time, did not increase the volume of flushing water, i.e. operating costs. Conclusions. Based on the results of the developed semi-empirical model, the design and technological parameters of granular filters for recycling of wastewater from the distilleries were determined, which became the basis for developing a new filter design for water purification from cyanobacteria cells and colonies. The high efficiency of the developed design of the clarifying filter - phytoplankton retainer was experimentally proved. The use of the developed filter increases the economic efficiency of the circulating use of the wastewater from Chervonoslobidsky distillery by 1.3 - 1.5 times compared to the market offers of mechanical filters.

More Papers Like This

Article Tier 2

The Effect of Filter Media Size and Loading Rate to Filter Performance of Removing Microplastics using Rapid Sand Filter

AI summary Read the abstract

This study evaluated how filter media size and hydraulic loading rate affect rapid sand filter performance in removing microplastics from water. Smaller sand media (0.39 mm) and lower loading rates achieved greater MP removal, suggesting that optimizing these parameters can improve conventional water treatment for plastic particles.

Article Tier 2

Evaluation of a Water Treatment System for Removing Microplastic in an Aqueous Media

AI summary Read the abstract

Researchers evaluated the microplastic removal efficiency of a hybrid water treatment system combining a Bradley-type hydrocyclone, sand filter, and polymeric microfiltration membrane, applying mass balance equations and solid-liquid separation models to determine removal performance across different MP size fractions.

Article Tier 2

Understanding and Improving Microplastic Removal during Water Treatment: Impact of Coagulation and Flocculation

AI summary Read the abstract

Researchers systematically tested coagulation and flocculation for removing microplastics from drinking water, finding that removal efficiency depended strongly on plastic particle size and whether particles had been weathered, with smaller pristine particles being the hardest to remove.

Article Tier 2

Removal efficiency of micro- and nanoplastics (180 nm–125 μm) during drinking water treatment

AI summary Read the abstract

Researchers tested how effectively standard drinking water treatment processes remove micro- and nanoplastics ranging from 180 nanometers to 125 micrometers. They found that coagulation and sedimentation alone removed less than 2% of plastic particles, while granular filtration was far more effective, achieving 87% to nearly 100% removal depending on particle size. The study also found that biofilm formation on microplastics significantly improved their removal during coagulation treatment.

Article Tier 2

[Research Progress on Removal of Microplastics by Filtration in Drinking Water Treatment].

AI summary Read the abstract

This review examines how media filtration at drinking water treatment plants removes microplastics, evaluating filter types, operating conditions, and removal efficiencies reported in the literature. It identifies filtration as a scalable, cost-effective barrier for MP removal and discusses optimisation strategies to improve performance.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper