0
Article Tier 2 Detection Methods Food & Water Remediation Sign in to save

Microplastic analysis in drinking water based on fractionated filtration sampling and Raman microspectroscopy

Environmental Science and Pollution Research 2021 102 citations

AI summary Read the abstract

A validated analytical workflow for detecting microplastics down to 5 µm in drinking water was developed using a portable filter cascade unit followed by two-step semi-automated Raman microspectroscopy, and was applied successfully to processed drinking water, tap water, and groundwater.

Study Type Environmental

Microplastics (MP) as emerging persistent pollutants were found in raw and drinking water worldwide. Since different methods were used, there is an urgent need for harmonized protocols for sampling, sample preparation, and analysis. In this study, a holistic and validated analytical workflow for MP analysis in aqueous matrices down to 5 μm is presented. For sampling of several cubic meters of water, an easily portable filter cascade unit with different pore sizes (100-20-5 μm) was developed and successfully applied for the sampling of three processed drinking waters, two tap waters and one groundwater. The size distribution and polymer types of MP were determined using a two-step semi-automated Raman microspectroscopy analysis. For quality control, comprehensive process blanks were considered at all times and a recovery test yielded an overall recovery of 81%. The average concentration of identified MP was 66 ± 76 MP/m ranging from 1 MP/m to 197 MP/m. All found concentrations were below the limit of quantitation (LOQ) of 1880 MP/m. The majority consisted of PE (86% ± 111%) while comparatively low numbers of PET (10% ± 25%), PP (3% ± 6%), and PA (1% ± 4%) were found. 79% of all particles were smaller than 20 μm. In summary, this study presents the application of a workflow for sampling and analysis of MP down to 5 μm with first results of no significant contamination in drinking water and groundwater.

More Papers Like This

Article Tier 2

Do drinking water plants retain microplastics? An exploratory study using Raman micro-spectroscopy

AI summary Read the abstract

Researchers quantified microplastic retention at a Danish groundwater-fed drinking water treatment plant using Raman spectroscopy, finding that the plant reduced but did not eliminate microplastic particles down to 1 micron in size, with some microplastics present in the treated drinking water output.

Article Tier 2

Microplastic and nanoplastic analysis in drinking water and indoor air with Raman micro-spectroscopy

AI summary Read the abstract

Raman micro-spectroscopy was used to detect and characterize micro- and nanoplastics in drinking water and indoor air, demonstrating the technique's value for assessing human exposure to plastic particles across multiple environments.

Article Tier 2

Identifying microplastic particle in the drinking water using Raman spectroscopy method

AI summary Read the abstract

This Indonesian study used Raman spectroscopy to identify and analyze microplastic content in drinking water and its sources, addressing concerns about plastic particle ingestion through contaminated beverages. Microplastics as small as 5 mm were detected and characterized, with potential health effects including hormonal imbalances and cardiovascular disease noted.

Article Tier 2

Microplastics Detection in Streaming Tap Water with Raman Spectroscopy

AI summary Read the abstract

Researchers demonstrated that Raman spectroscopy can detect and identify microplastic particles in streaming tap water in real time, offering a rapid non-destructive method for monitoring plastic contamination in drinking water.

Article Tier 2

Analysis of microplastics in drinking water and other clean water samples with micro-Raman and micro-infrared spectroscopy: minimum requirements and best practice guidelines

AI summary Read the abstract

Researchers compiled best-practice guidelines for detecting and quantifying microplastics in drinking water using micro-Raman and micro-infrared spectroscopy, establishing minimum requirements for sample preparation, measurement parameters, and data reporting to improve comparability across studies.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper