We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Nanoplastics adsorption and removal efficiency by granular activated carbon used in drinking water treatment process
AI summary Read the abstract
Researchers tested granular activated carbon used in drinking water treatment for its ability to adsorb polystyrene nanoplastics, finding efficient removal in both ultrapure water and surface water from Lake Geneva, with adsorption following Langmuir isotherm behavior.
In this study Granular Activated Carbon (GAC) used in drinking water treatment processes is evaluated for its capacity to adsorb and remove polystyrene (PS) nanoplastics. Batch experiments are conducted in ultrapure and surface water from Lake Geneva, currently used as drinking water resources. Equilibrium and kinetic studies are conducted to understand adsorption mechanisms and limiting factors. Our results show that in ultrapure water the adsorption and removal of PS nanoplastics are mainly due to electrostatic interactions between the positively charged nanoplastics and negatively charged GAC. It is found that the adsorption capacity increases with nanoplastic concentration with a maximum adsorption capacity of 2.20 mg/g. The adsorption kinetics follows a pseudo-second-order model and indicates that the intra-particle diffusion is not the only rate-controlling step. The Langmuir isotherm indicates that nanoplastics are adsorbed as a homogeneous monolayer onto the GAC surface with a maximum monolayer adsorption capacity of 2.15 mg/g in agreement with the experimental value. In Lake Geneva water the adsorption capacity and removal efficiency of PS nanoplastics are found three times higher than in ultrapure water and increase significantly with increasing PS nanoplastics concentration with a maximum adsorption capacity of 6.33 mg/g. This improvement in adsorption capacity is due to the presence of Dissolved Organic Matter (DOM), resulting in PS surface charge modification, presence of divalent ions making possible the adsorption of PS-DOM complexes, and, aggregation of PS nanoplastics. The kinetic pseudo-second-order and intra-particle diffusion provide a good correlation with the experimental data. In contrast, neither Langmuir nor Freundlich isotherms describe in a satisfactory way the adsorption of nanoplastics by GAC. This study reveals that GAC produced from renewable sources can be considered as a moderate adsorbent for the removal of PS nanoplastics in water treatment plants and that the presence of DOM and cationic species play a major role.
More Papers Like This
Transport behavior of nanoplastics in activated carbon column
AI summary Read the abstract
Researchers investigated the transport and retention of nanoplastics through granular activated carbon columns used in drinking water treatment. Nanoplastics were partially retained in activated carbon but their behavior depended on particle surface charge and solution chemistry, with implications for drinking water safety.
Fate and removal efficiency of polystyrene nanoplastics in a pilot drinking water treatment plant
AI summary Read the abstract
Researchers investigated how effectively a pilot-scale drinking water treatment plant removes polystyrene nanoplastics. The study found that sand and activated carbon filtration alone achieved 88.1% removal, but adding a coagulation step dramatically improved removal efficiency to 99.4%, with most nanoplastics captured during the sand filtration process.
Hybrid treatment of polystyrene nanoplastics by coagulation-coupled with adsorption
AI summary Read the abstract
Tiny plastic particles called nanoplastics can end up in our drinking water and may carry harmful chemicals into our bodies, making them a growing health concern. This study found that combining two water treatment steps—first clumping the particles together with a chemical, then filtering them through activated carbon (similar to charcoal filters)—removed over 99% of these plastic particles, far better than either method alone. This suggests water treatment plants could use this combined approach to more effectively protect drinking water from nanoplastic contamination.
Adsorption performance of nanoplastics in carbon filtration column
AI summary Read the abstract
This study investigated the adsorption and removal of polystyrene nanoplastics in a carbon filtration column under varying experimental conditions including pH and ionic strength. Results showed that activated carbon effectively retained polystyrene nanoparticles, with column performance depending significantly on water chemistry.
Paving roads with recycled plastics: Microplastic pollution or eco-friendly solution?
AI summary Read the abstract
This study assessed the capability of granular activated carbon filtration to remove nanoplastics from drinking water, finding approximately 85% removal efficiency for particles below 1 micrometer. Removal was lower for smaller, hydrophilic particles that resist adsorption.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.