0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Nanoplastics Policy & Risk Remediation Sign in to save

CarboxylatedPolystyrene Particles for Plastic Standardsin Laser Ablation ICP–MS Trace Elements Analysis: AnalyticalAspects and Environmental Relevance

Figshare 2025 Score: 38 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Maud Gautier (10479445), Sandra Mounicou (2027851), Javier Jiménez-Lamana (3115815), Stéphanie Reynaud (4014335), Bruno Grassl (2192983)

Summary

Researchers developed a novel calibration method using carboxylated polystyrene nanoparticles as plastic standards for laser ablation ICP-MS analysis of trace metals in polymers, addressing the lack of suitable reference materials for direct solid-state analysis of microplastics.

Polymers

Reliable quantification of trace metals in polymers by direct solid-state analysis remains limited by the lack of suitable reference materials. In this study, we introduce a novel method for producing standardized plastic samples specifically designed for the calibration and analysis of trace metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Carboxylated polystyrene (PS) nanoparticles, capable of adsorbing metal ions from solution, were synthesized and evaluated. The trace metal adsorption capabilities of these PS nanoparticles were assessed with adsorption isotherms fit well with the Freundlich model. The study focused cobalt (Co2+), copper (Cu2+), and lead (Pb2+) The adsorption constants were found to be 0.15 for Co2+, 0.48 for Cu2+, and 3.63 for Pb2+. The metal-sorbed PS nanoparticles were then processed into disc-shaped plastics via hot-press molding, and LA-ICP-MS analysis confirmed the homogeneous metal distribution both at the surface and in depth, with relative standard deviations (RSD) of less than 5% for all metals analyzed. Calibration curves for Pb2+ (1220–4400 mg kg–1), Cu2+ (210–600 mg kg–1), and Co2+ (67–220 mg kg–1) showed strong linear relationships, with R2 values of 0.96 for Pb2+, 0.95 for Cu2+, and 0.94 for Co2+. The methodology limits of detection (LOD) were determined to be 113 mg kg–1 for Pb2+, 93 mg kg–1 for Cu2+, and 23 mg kg–1 for Co2+. The developed standards enabled the calibration of analytical instruments and thus improve the reliability of assessments concerning the contamination of environments with metal-laden microplastics.

Share this paper