Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Marine & Wildlife Nanoplastics Policy & Risk Sign in to save

Detection and Quantification of Nonlabeled Polystyrene Nanoparticles Using a Fluorescent Molecular Rotor

Analytical Chemistry 2021 31 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 40 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Angélique Moraz, Florian Breider

Summary

Researchers developed a fluorescent molecular rotor (DCVJ) detection method for unlabeled polystyrene nanoplastics, finding that nanoplastic presence generates a distinct second emission peak at 620 nm that enables quantification with a detection limit of 0.1 mg/L in pure water.

Plastic pollution has reached alarming levels in recent years. While macro- and microplastic pollution are attested and studied since the 1970s, much less is known about the associated nanoscopic fragments. Due to their ability to cross biological barriers and their extended surface area-to-volume ratio, nanoplastics (NPs) are currently considered as one of the major threats for aquatic and terrestrial environments. Therefore, analytical tools are urgently needed to detect and quantify NPs. In this study, a method exploiting the dependence of the fluorescence quantum yield of a probe, namely, 9-(2,2-dicyanovinyl)julolidine (DCVJ), toward its microenvironment was assessed to detect and quantify polystyrene nanoplastics (PSNs). In the presence of PSNs and after excitation at 450 nm, the single-emission band fluorescent molecular rotor (FMR) emission spectrum displays a second peak at 620 nm, which increases with the concentration of PSNs. In pure water, a limit of detection and quantification range of 475-563 μg·L-1 and 1.582-1.875 mg·L-1, respectively, were obtained for 49 nm diameter polystyrene beads (PSB49). The results associated with 100 nm diameter PSNs amount to 518 μg·L-1 and 1.725 mg·L-1. The robustness of the method toward different parameters, the complexity of the matrix, and the PSN characteristics was also assessed. Finally, the method was applied on biological samples. While PSB49 quantification was achieved using radish sprouts at concentrations up to 200 mg·L-1, it was more challenging when handling mussel tissues. This work presents the feasibility to quantify PSNs using DCVJ fluorescence. It paves the way to new perspectives in the challenging field of NPs.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Detection of polystyrene nanoplastics in biological tissues with a fluorescent molecular rotor probe

A fluorescent dye was developed to detect polystyrene nanoplastics in biological tissues, offering a simpler alternative to existing methods. This tool could help scientists better understand how nanoplastics spread through living organisms and accumulate in organs.

Article Tier 2

Determination of polystyrene nanospheres and other nanoplastics in water via binding with organic dyes by capillary electrophoresis with laser-induced fluorescence detection

Researchers developed a new capillary electrophoresis method using fluorescent organic dyes to quantitatively detect polystyrene nanospheres and other nanoplastics in water samples, successfully differentiating them from microplastics and colloidal particles.

Article Tier 2

A one-step strategy for rapid detection of sub-50 nm polystyrene nanoplastics using nanobody-based homogeneous immunoassay

Researchers developed a rapid, one-step detection method for sub-50 nanometer polystyrene nanoplastics using engineered nanobodies combined with NanoLuciferase technology. The system achieved a detection limit of 0.25 micrograms per milliliter with results in under 30 minutes, representing a significant advance in the ability to detect very small nanoplastic particles in environmental samples.

Clinical Trial Tier 1

Polarization transmission characteristics of polystyrene microplastics in aqueous environments

This study investigated how polarized light interacts with polystyrene microplastic particles suspended in water. While primarily a detection methods paper, it advances techniques for identifying microplastics in water and biological fluids like blood and urine, which is essential for accurately measuring human exposure levels.

Article Tier 2

Sensors for Polystyrene Nanoplastics Detection in Water Samples

This review assessed recent advances in sensor and biosensor technologies for detecting polystyrene nanoplastics in complex aquatic samples. The authors identified optical, electrochemical, and surface-enhanced Raman approaches as the most promising strategies, while highlighting the ongoing challenges of matrix interference and low-concentration detection limits.