Evaluation and optimization of the influence of silver cluster ions on the MALDI-TOF-MS analysis of polystyrene nanoplastic polymers
Summary
Researchers optimized MALDI-TOF-MS analysis of polystyrene nanoplastics by evaluating silver cationization reagents, finding that silver cluster ion interference could be minimized through careful selection of matrix and silver salt combinations.
In the analysis of polystyrene nanoplastics (PSNs), a nonpolar polymer (NP), using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), silver salts were used as cationization reagents and simultaneously brought the potential problems of silver clusters that interfered with the PSN signal of MS. To detect PSNs, silver trifluoroacetate (AgTFA) and silver nitrate (AgNO3) were mixed with five polar matrices, namely 2-(4-hydroxyphenylazo) benzoic acid (HABA), dithranol (DI), sinapic acid (SA), trans-3-indoleacrylic acid (IAA), and 2,5-dihydroxybenzoic acid (DHB), and three nonpolar matrices, namely pyrene (PRN), anthracene (ATH) and acenaphthene (ACTH). The results showed that silver salt cluster ions were detected in the range of m/z 1000-4000. Five polar matrices with silver salts produced silver clusters, which interfered with the signals in the mass spectrum of PSNs, but the combination of these matrices with copper II chloride (CuCl2) salt did not produce copper-related clusters. However, the use of nonpolar matrices such as PRN, ATH or ACTH significantly decreased the signals of silver salt cluster ions, and this alteration of matrix types is considered a promising optimization approach for silver cluster ions. The nonpolar matrix conditions were optimized without producing silver cluster ions and the optimal detection conditions were found to be under nonpolar matrices (e.g., pyrene) with silver salts (e.g., AgTFA). The results suggest that when polar matrices, such as HABA, DI, SA, IAA, and DHB, are combined with silver salts in MALDI-TOF-MS analysis, silver-related clusters are detected in the range of m/z 1000-4000. Inhibition of the production of silver cluster ions can be achieved by the use of a nonpolar matrix (e.g., PRN) or polar matrix (e.g., DHB) with copper salts.
Sign in to start a discussion.
More Papers Like This
High-performance micro/nanoplastics characterization by MALDI-FTICR mass spectrometry
Researchers developed a MALDI-FTICR mass spectrometry method for high-precision chemical identification of micro- and nanoplastics, demonstrating unambiguous characterization of multiple polymer types including polystyrene and polyethylene terephthalate even at very small particle sizes.
Thermal fragmentation enhanced identification and quantification of polystyrene micro/nanoplastics in complex media
Researchers developed a method using thermal fragmentation combined with MALDI-TOF mass spectrometry to identify and quantify polystyrene micro/nanoplastics in complex media, enabling reliable fingerprint-based detection and quantification down to nanoplastic size ranges.
Detecting Polystyrene Nanoparticles in EnvironmentalSamples: A Comprehensive Quantitative Approach Based on TD-PTR-MSand Multivariate Standard Addition
Researchers developed a quantitative analytical workflow for detecting polystyrene nanoparticles in complex environmental matrices using thermal desorption-proton-transfer reaction-mass spectrometry (TD-PTR-MS) combined with multivariate standard addition. The approach addressed matrix interference challenges by exploiting the chemical selectivity of TD-PTR-MS to distinguish nanoplastic signals from the surrounding organic compounds.
Detecting Polystyrene Nanoparticles in Environmental Samples: A Comprehensive Quantitative Approach Based on TD-PTR-MS and Multivariate Standard Addition
Scientists developed an analytical method combining thermal desorption, mass spectrometry, and multivariate statistics to accurately quantify polystyrene nanoplastics in complex environmental samples where other organic compounds can interfere with the signal. The workflow used non-negative matrix factorization to separate nanoplastic signals from background organic chemistry, enabling reliable quantification in real-world samples. Robust quantification methods for nanoplastics are a prerequisite for understanding human and environmental exposure, making this analytical advance scientifically significant.
Extraction and quantification of polystyrene nanoplastics from biological samples
Researchers developed a new method to extract and quantify polystyrene nanoplastics from biological samples using alkaline digestion, centrifugation, cloud point extraction, and single-particle ICP-MS with gold nanoparticle labeling. The method achieved recovery rates above 80% and was validated in tissue samples, addressing a major analytical gap for nanoplastic detection in complex biological matrices.