We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Extraction and Pyrolysis-GC-MS analysis of polyethylene in samples with medium to high lipid content
AI summary Read the abstract
Researchers developed an improved method for extracting and quantifying polyethylene in food samples with medium to high fat content using pyrolysis-gas chromatography mass spectrometry. The study found that fats produce the same pyrolysis products as polyethylene, creating significant interference, and their new extraction protocol reduced detection limits from 380 to 10 micrograms per gram.
While it is recognised that humans are constantly exposed to plastics, there are limitations in understanding the extent of this exposure, particularly dietary exposure. This lack of information is partly due to challenges with the analysis of complicated matrices. This study aimed to assess the impact of medium to high lipid content (> 3%) food samples on the accurate quantification of polyethylene (PE), using pyrolysis-gas chromatography mass spectrometry, and develop an alternative sample processing strategy. Analysis of saturated, monounsaturated and polyunsaturated fats was demonstrated to form the same pyrolysis products as PE, producing a significant interference hindering quantification. An extraction protocol was developed that involves enzyme digestion to break the lipids into smaller chain fatty acids, removal of these interferences with pressurised liquid extraction washes, before a final extraction of the PE by pressurised liquid extraction. This new method was validated through the analysis of three medium- to high-fat content foods: cow’s milk, eggs and lamb meat, where PE recoveries were acceptable (104% to 127%). Method detection limits were also significantly reduced from 1.9 to 0.05 µg/injection (380 to 10 µg/g) with the new protocol, through the removal of matrix background. PE traces were observed in the three food matrices of 72-240 µg/g, significantly reduced as compared to samples extracted with the old method where concentrations of 12-32 mg/g were calculated, demonstrating the potential for overestimation of dietary exposure. Finally, a simple protocol is reported for future studies to (i) determine if an interference is present and (ii) sample processing methods to remove identified interferences.
More Papers Like This
Opportunities to improve polyethylene microparticle analysis by pyrolysis-gas chromatography/mass spectrometry
AI summary Read the abstract
This study demonstrates that pyrolysis-GC/MS analysis of polyethylene microplastics is prone to false positives because lipids, saturated fatty acids, and waxes produce identical pyrolysis products to PE, causing software algorithms relying on non-unique qualifier ions to misidentify these materials. The findings call for improved data interpretation protocols and supplementary verification steps to ensure reliable PE detection across environmental matrices.
QuantifyingNanoplastics and Microplastics in Foodand Beverages Using Pyrolysis-Gas Chromatography–Mass Spectrometry:Challenges and Implications
AI summary Read the abstract
Researchers evaluated pyrolysis-GC/MS for quantifying nanoplastics and microplastics in common foods and beverages, assessing sensitivity and detection limits across polymer types. The method successfully detected multiple polymer types in food samples but showed limitations for nanoplastics at very low concentrations, highlighting gaps in current dietary exposure assessment.
Determination of the microplastic content in Mediterranean benthic macrofauna by pyrolysis-gas chromatography-tandem mass spectrometry
AI summary Read the abstract
Researchers developed an analytical method combining pyrolysis with gas chromatography-tandem mass spectrometry (Py-GC-MS/MS) for quantifying six common plastic polymers in Mediterranean benthic macrofauna with minimal sample preparation. The method achieved lower detection limits than conventional Py-GC/MS for six polymers including polyethylene and polypropylene, enabling more sensitive monitoring of MP contamination in seafloor organisms.
Optimization of an Analytical Protocol for the Extraction of Microplastics from Seafood Samples with Different Levels of Fat
AI summary Read the abstract
Researchers developed and optimized an analytical extraction protocol for microplastics from seafood samples with varying fat content, testing the method on fresh and canned fish and molluscs. They found that fat-rich matrices required additional lipid removal steps to achieve reliable extraction efficiency, and validated a protocol suitable for high-fat seafood that reduces matrix interference while maintaining microplastic recovery.
Py-GC-MS/MS quantification of microplastics in vertebrate tissues: Addressing false positives of polyethylene
AI summary Read the abstract
Researchers developed an improved analytical method using pyrolysis gas chromatography with tandem mass spectrometry to quantify small microplastics in bird tissues. They addressed a known problem of false positive polyethylene readings caused by lipids in biological samples by using longer carbon chain markers. The method was validated in Yellow-legged Gulls and provides a more reliable way to measure microplastic contamination in vertebrate organisms.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.