0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Sign in to save

How to trust size distributions obtained by single particle inductively coupled plasma mass spectrometry analysis

Analytical and Bioanalytical Chemistry 2022 22 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 40 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Ana C. Giménez-Ingalaturre, Khaoula Ben-Jeddou, Josefina Pérez‐Arantegui, María S. Jiménez, Eduardo Bolea, Francisco Laborda

Summary

Researchers identified a critical flaw in single particle ICP-MS — a technique used to measure the size and concentration of nanoparticles in water — showing that incomplete detection of small particles can produce misleadingly clean-looking size distributions. They developed a validation method using successive dilutions to confirm whether measured data accurately represents the full particle population, which is essential for reliable nanoplastic detection.

Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) is a technique widely used to obtain direct information about the number concentration and the size distribution of nanoparticles in liquid suspensions. However, its methods still lack clear quality control strategies to confirm the validity of the information derived from them. Only the detection of the complete size distribution of the nanoparticles in a sample over the size critical value ensures obtaining unbiased quantitative information, otherwise information should be restricted to report the presence of nanoparticles over a certain size and number concentration since their actual total number concentration is underestimated and the size overestimated. Under the latter conditions, data processing produces histograms showing the tails of the incomplete size distributions, although apparently, complete distributions can also be obtained when particle events are recorded as peaks, as reported here for the first time. The occurrence of these misleading situations must be critically evaluated for each SP-ICP-MS analysis. An approach, based on estimation of size critical values and successive dilutions, is proposed for the assessment of the validity of the quantitative information obtained, together with specific criteria for reconsidering the information that can be derived from those measurements. The approach was verified with different case studies and applied to the analysis of complex nanomaterials, confirming the validity of the reported information by comparison with other techniques. A calculation tool is also included to facilitate the estimation of size critical values under experimental conditions.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Extending the Linear Dynamic Range of Single Particle ICP-MS for the Quantification of Microplastics

Researchers developed an improved method using single particle inductively coupled plasma mass spectrometry to detect and measure microplastics across a wider size range than previously possible. By extending the linear dynamic range of the technique, they could more accurately size and count larger microplastic particles. The advancement addresses a key limitation in current microplastic analytical methods and could improve environmental monitoring.

Article Tier 2

Extending theLinear Dynamic Range of Single ParticleICP-MS for the Quantification of Microplastics

Researchers extended the linear dynamic range of single-particle ICP-MS for microplastic quantification to enable detection across a wider concentration range with high throughput. The method improvements allow more accurate characterisation of MP particle number and size distributions in environmental and biological samples.

Article Tier 2

Nanoplastics prepared with uniformly distributed metal-tags: a novel approach to quantify size distribution and particle number concentration of polydisperse nanoplastics by single particle ICP-MS

Researchers developed a new method for creating nanoplastic test particles with embedded metal tags, allowing scientists to precisely measure the size and number of nanoplastics using single-particle mass spectrometry. The particles have realistic irregular shapes and varied sizes, unlike the uniform spheres typically used in lab studies. This tool will help researchers more accurately study how nanoplastics behave in environmental and health experiments.

Article Tier 2

Catching particles by atomic spectrometry: Benefits and limitations of single particle - inductively coupled plasma mass spectrometry

This review evaluates single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) as an analytical technique, highlighting its expanding capabilities for detecting, sizing, and quantifying metal-based nanoparticles and emerging applications in microplastic and carbon-based particle analysis.

Article Tier 2

Investigation and Correction of Size-Dependent Transport Efficiencies of Microparticles in SP ICP-MS Analysis

Size-dependent transport effects were identified and corrected for in microplastic sampling methodologies, showing that standard collection nets and filters underrepresent certain size fractions. Addressing these biases is necessary for generating accurate estimates of microplastic abundance across size ranges.

Share this paper