0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Environmental Sources Sign in to save

Precision Ventilation for an Open-Plan Office: A Study of Variable Jet Interaction between Two Active Chilled Beams

Sustainability 2022 5 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Haider Latif, Samira Rahnama, Alessandro Maccarini, Craig R. Bradshaw, Göran Hultmark, Peter V. Nielsen, Alireza Afshari

Summary

Researchers designed a precision ventilation system using active chilled beams that creates customized microclimatic zones in open-plan offices, allowing different temperature preferences for occupants with different activity levels. Variable jet interaction between two units was manipulated to direct airflow where needed. The system improves thermal comfort while reducing the energy cost of whole-room climate control.

Precision ventilation is developed to achieve thermal comfort for occupants in an office by creating micro-climate zones. The present study aims to achieve individual thermal comfort for occupants with different metabolic rates by using higher airspeeds for enhancing heat transfer. The variable jet interaction between two ACBs with JetCone adjustments cause higher velocity jets to reach different regions of the occupied zone. The colliding jets from the center of a thermal isolated room were moved towards different zones in an office configuration with a constant room temperature of 23 °C. This study was conducted for five different cases in a room divided into four zones according to occupants’ metabolic rates. The experimental and CFD results show that occupants facing symmetrical airflow distribution and with a constant 1.2 metabolic rate (Case 1) had a similar predicted mean vote (PMV) index. The zones with higher-metabolic-rate occupants, i.e., 1.4 met and 1.6 met in cases 2 and 3 were exposed to air velocities up to 0.4 and 0.5 m/s, respectively. In case 4, the air velocity in the single zone with 1.6 met occupants was raised to 0.6 m/s by targeted airflow distribution achieved by adjusting JetCones. These occupants with higher metabolic rates were kept thermally neutral, in the −0.5 to +0.5 PMV range, by pushing the high velocity colliding jets from the center towards them. In case 5, the results showed that precision ventilation can maintain the individual thermal comfort of up to three different zones (in the same office space) by exposing the occupants with metabolic rates of 1.2, 1.4, and 1.6 met to airspeeds of 0.15, 0.45, and 0.55 m/s, respectively.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Experimental Evaluation of the Impacts of Suspended Particle Device Smart Windows with Glare Control on Occupant Thermal and Visual Comfort Levels in Winter

Researchers experimentally evaluated how suspended particle device (SPD) smart windows affect occupant thermal and visual comfort in winter conditions, comparing occupant responses across different window configurations to assess the performance of adaptive glazing technologies in real building environments.

Article Tier 2

Microplastic Fallout in Different Indoor Environments

Researchers tracked microplastic fallout in indoor environments (dormitory, office, corridor) over three months and found that higher human activity on workdays and airflow from air conditioning increased microplastic deposition rates, identifying indoor air as a significant exposure route.

Article Tier 2

Suggesting a Stochastic Fractal Search Paradigm in Combination with Artificial Neural Network for Early Prediction of Cooling Load in Residential Buildings

Researchers developed a hybrid model combining artificial neural networks with a stochastic fractal search algorithm (SFS-ANN) for early prediction of building cooling loads, finding it outperformed benchmark optimization algorithms and offering a practical tool for energy-efficient residential building design.

Article Tier 2

Exposure Assessment of Infectious Virus Particles in a Classroom Setting Using Computational Fluid Dynamics Model

This computational fluid dynamics study models how infectious virus particles spread in classrooms under different ventilation configurations, finding that maintaining a ventilation-to-AC flow ratio of 2.8 can reduce viral particle concentrations by up to 93%. It is not about microplastics and is a false positive for microplastic relevance.

Article Tier 2

How human thermal plume influences near-human transport of respiratory droplets and airborne particles: a review

Researchers reviewed evidence on how the human thermal plume — the column of warm air rising from body surfaces — controls airborne particle and respiratory droplet transport in the breathing zone, concluding that it facilitates COVID-19 airborne transmission in indoor spaces by elevating small particles into the inhalation zone.

Share this paper