Analysis of Microplastics in Aquatic Shellfish by Pyrolysis–Gas Chromatography/Mass Spectrometry after Alkali Digestion and Solvent Extraction
Summary
Researchers developed a pyrolysis-gas chromatography/mass spectrometry method for detecting trace microplastics in aquatic shellfish, achieving 74-102% recovery rates for nylon microplastics after alkali digestion and solvent extraction.
Microplastics are harmful to both marine life and humans. Herein, a pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS) technique for the detection of microplastics in aquatic shellfish is demonstrated. The organic matter in aquatic shellfish was removed by alkali digestion. Subsequently, using hexafluoroisopropanol as the extraction solvent, the extraction method was optimized. The influence of the digestion process on the nature of microplastics was investigated by analyzing the samples before and after the alkali treatment via infrared spectrometry, laser particle sizing, and scanning electron microscopy. Spiked recovery experiments and an analysis of actual samples were performed using PA6 and PA66 as analytes. A quantitative analysis of the characteristic ion fragment produced by high-temperature cracking was performed after chromatographic separation and mass spectrometry identification. The linear range of this method for PA6 and PA66 was 2-64 μg. The limits of detection of PA6 and PA66 were 0.2 and 0.6 μg, while the limits of quantitation were 0.6 and 2.0 μg, respectively. Recovery ranged from 74.4 to 101.62%, with a precision of 4.53-7.56%. The results suggest that the Py-GC/MS technique is suitable for the analysis and detection of trace microplastics in aquatic shellfish.
Sign in to start a discussion.
More Papers Like This
Determination of the microplastic content in Mediterranean benthic macrofauna by pyrolysis-gas chromatography-tandem mass spectrometry
Researchers developed an analytical method combining pyrolysis with gas chromatography-tandem mass spectrometry (Py-GC-MS/MS) for quantifying six common plastic polymers in Mediterranean benthic macrofauna with minimal sample preparation. The method achieved lower detection limits than conventional Py-GC/MS for six polymers including polyethylene and polypropylene, enabling more sensitive monitoring of MP contamination in seafloor organisms.
Microplastic Polymer Mass Fractions in Marine Bivalves: From Isolation to Hazard Risk
This review examines methods for isolating and quantifying microplastics in marine bivalves such as mussels and oysters, focusing on efficient digestion procedures and detection techniques. The study highlights microwave-assisted methods and pyrolysis gas chromatography-mass spectrometry as promising approaches for determining polymer mass fractions, and discusses the health risks associated with microplastic contamination in seafood consumed by humans.
Identification and quantification of microplastics in the clam Chamelea gallina using different analytical techniques
Researchers developed and compared protocols for extracting and quantifying microplastics in the clam Chamelea gallina using Raman microspectroscopy and analytical pyrolysis coupled with gas chromatography/mass spectrometry (Py-GC/MS), documenting the advantages and limitations of each analytical technique.
Optimization, performance, and application of a pyrolysis-GC/MS method for the identification of microplastics
Researchers optimized a pyrolysis-GC/MS method for identifying and quantifying microplastics in environmental samples, improving the reliability of polymer identification especially for small particles that are difficult to classify visually. The improved method is particularly valuable for analyzing the smallest microplastic size fractions that dominate by number in marine environments.
Microplastics analysis in environmental samples – recent pyrolysis-gas chromatography-mass spectrometry method improvements to increase the reliability of mass-related data
This study improved pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) methods for measuring mass-related microplastic data in environmental samples, enhancing reliability and sensitivity for trace-level analysis. Better analytical methods are essential for accurately quantifying microplastic contamination across diverse environmental matrices.