0
Article Tier 2 Detection Methods Environmental Sources Policy & Risk Sign in to save

Particle and Gas Phase Sampling of Pcdd/fs and Pcbs by Activated Carbon Fiber and Gc/ms Analysis

AI summary Read the abstract

This study validated activated carbon fiber (ACF) filters as an alternative sampling medium for measuring polychlorinated dioxins, furans, and PCBs in air, overcoming limitations of the conventional quartz fiber filter plus polyurethane foam method. Unlike standard approaches, ACF sampling enables study of gas-particle phase distribution rather than just total quantification of these semi-volatile persistent organic pollutants. Results demonstrated that ACF coupled with GC/MS analysis provides reliable performance for characterizing the atmospheric partitioning of these compounds.

Polymers

Abstract Polychlorodibenzo- p -dioxins (PCDDs), polychlorodibenzofurans (PCDFs) and polychlorobiphenyls (PCBs) are semi-volatile compounds and can be partitioned in the atmosphere between the gas and particulate phase, due to their physicochemical properties. For this reason, the reference standard methods for air sampling include a quartz fiber filter (QFF) for the particulate and a polyurethane foam (PUF) cartridge for the vapor phase, and it is the classical and most popular sampling method in the air. Despite the presence of the two adsorbing media, this method cannot be used for the study of the gas-particulate distribution, but only for a total quantification. This study presents the results and the performance aim to validate an activated carbon fiber (ACF) filter for the sampling of PCDD/Fs and PCBs using laboratory and field tests. The specificity, precision and accuracy of the ACF in relation to the QFF + PUF were evaluated through the isotopic dilution technique, the recovery rates and the standard deviations. Then the ACF performance was assessed on real samples, in a naturally contaminated area, through parallel sampling with the reference method (QFF + PUF). The QA/QC was defined according to the standard methods ISO 16000-13 and − 14 and EPA TO4A and 9A. Data confirmed that ACF meets the requirements for the quantification of native POPs compounds in atmospheric and indoor samples. In addition, ACF provided accuracy and precision comparable to those offered by standard reference methods using QFF + PUF, but with significant savings in terms of time and costs.

More Papers Like This

Article Tier 2

Particle and gas phase sampling of PCDD/Fs and dl-PCBs by activated carbon fiber and GC/MS analysis

AI summary Read the abstract

Researchers validated an activated carbon fiber filter as an accurate, faster, and cheaper alternative to standard methods for collecting and measuring toxic dioxins and PCBs — persistent organic pollutants — in air samples. The new filter matched the precision of conventional methods while reducing the time and cost of environmental air monitoring.

Article

Developing new adsorbents for the passive sampling of organic pollutants in the atmosphere : comparison with existing systems

AI summary Read the abstract

This research develops and evaluates new sorbent materials for passive sampling devices used to monitor organic contaminants — including plastic-associated chemicals — in environmental water and sediment. The new adsorbents demonstrated improved uptake rates and selectivity compared to conventional materials under a range of field conditions. These advances could enhance the sensitivity and accuracy of environmental monitoring programs for plastic-derived pollutants.

Article Tier 2

ACFs-NH2 developed for dispersive solid phase extraction combined with Py-GC/MS for nanoplastic analysis in ambient water samples

AI summary Read the abstract

Researchers developed a sample preparation method using amino-functionalized activated carbon fibers paired with pyrolysis-gas chromatography/mass spectrometry to detect nanoplastics in water, achieving recovery rates above 98% for polystyrene nanoplastics in seawater with detection limits as low as 20 µg/L.

Article Tier 2

Magic extraction: solid-phase extraction and analytical pyrolysis to study polycyclic aromatic hydrocarbon and polychlorinated biphenyls in freshwater

AI summary Read the abstract

A new solventless solid-phase extraction method was tested for extracting polycyclic aromatic hydrocarbons and polychlorinated biphenyls from freshwater samples. The Magic Chemisorber material selectively captured these persistent organic pollutants without the need for large volumes of organic solvents. This cleaner analytical technique reduces hazardous waste while maintaining good recovery of target contaminants.

Article Tier 2

Assessment of low-density polyethylene and poly (ethylene-co-vinyl acetate) capability for the uptake Persistent Organic Pollutants (POPs) in atmospheric passive sampling devices

AI summary Read the abstract

Researchers evaluated EVA and low-density polyethylene polymers for uptaking persistent organic pollutants in passive atmospheric samplers, finding that EVA showed higher absorption capacity for organochlorine pesticides and polychlorinated biphenyls than LDPE.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper