Researchers validated an activated carbon fiber filter as an accurate, faster, and cheaper alternative to standard methods for collecting and measuring toxic dioxins and PCBs — persistent organic pollutants — in air samples. The new filter matched the precision of conventional methods while reducing the time and cost of environmental air monitoring.
Polychlorodibenzo-p-dioxins (PCDDs), polychlorodibenzofurans (PCDFs), and polychlorobiphenyls (PCBs) are semi-volatile compounds and can be partitioned in the atmosphere between the gas and particulate phase, due to their physicochemical properties. For this reason, the reference standard methods for air sampling include a quartz fiber filter (QFF) for the particulate and a polyurethane foam (PUF) cartridge for the vapor phase, and it is the classical and most popular sampling method in the air. Despite the presence of the two adsorbing media, this method cannot be used for the study of the gas-particulate distribution, but only for a total quantification. This study presents the results and the performance aim to validate an activated carbon fiber (ACF) filter for the sampling of PCDD/Fs and dioxin-like PCBs (dl-PCBs) using laboratory and field tests. The specificity, precision, and accuracy of the ACF in relation to the QFF + PUF were evaluated through the isotopic dilution technique, the recovery rates, and the standard deviations. Then the ACF performance was assessed on real samples, in a naturally contaminated area, through parallel sampling with the reference method (QFF + PUF). The QA/QC was defined according to the standard methods ISO 16000-13 and -14 and EPA TO4A and 9A. Data confirmed that ACF meets the requirements for the quantification of native POPs compounds in atmospheric and indoor samples. In addition, ACF provided accuracy and precision comparable to those offered by standard reference methods using QFF + PUF, but with significant savings in terms of time and costs.
Sign in to start a discussion.
More Papers Like This
Simple multi-residue analysis of persistent organic pollutants and molecular tracers in atmospheric samples
Researchers developed a streamlined analytical method to simultaneously detect a wide range of persistent organic pollutants and molecular tracers in air samples using gas chromatography. This multi-residue approach offers a more efficient way to monitor atmospheric contamination by hazardous chemicals.
A Facile and Rapid Strategy for Quantifying PCBs in Cereals Based on Dispersive Solid-Phase Extraction and Gas Chromatography–Mass Spectrometry: A Reference for Safety Concerns in Sustainable Textiles
Researchers developed a rapid method using dispersive solid-phase extraction and gas chromatography–mass spectrometry to detect 18 polychlorinated biphenyls in cereals, incorporating carbon nanotubes as a novel cleanup material to improve accuracy and reduce matrix interference.
Assessment of low-density polyethylene and poly (ethylene-co-vinyl acetate) capability for the uptake Persistent Organic Pollutants (POPs) in atmospheric passive sampling devices
Researchers evaluated EVA and low-density polyethylene polymers for uptaking persistent organic pollutants in passive atmospheric samplers, finding that EVA showed higher absorption capacity for organochlorine pesticides and polychlorinated biphenyls than LDPE.
Magic extraction: solid-phase extraction and analytical pyrolysis to study polycyclic aromatic hydrocarbon and polychlorinated biphenyls in freshwater
A new solventless solid-phase extraction method was tested for extracting polycyclic aromatic hydrocarbons and polychlorinated biphenyls from freshwater samples. The Magic Chemisorber material selectively captured these persistent organic pollutants without the need for large volumes of organic solvents. This cleaner analytical technique reduces hazardous waste while maintaining good recovery of target contaminants.
ACFs-NH2 developed for dispersive solid phase extraction combined with Py-GC/MS for nanoplastic analysis in ambient water samples
Researchers developed a sample preparation method using amino-functionalized activated carbon fibers paired with pyrolysis-gas chromatography/mass spectrometry to detect nanoplastics in water, achieving recovery rates above 98% for polystyrene nanoplastics in seawater with detection limits as low as 20 µg/L.