0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Sign in to save

Colourimetric Plate Assays Based on Functionalized Gelatine Hydrogel Useful for Various Screening Purposes in Enzymology

International Journal of Molecular Sciences 2022 6 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Karolina Labus, Halina Maniak

Summary

Researchers developed hydrogel-based colorimetric assays for enzyme screening, using gelatin functionalized with different substrates to enable fast visual identification of enzyme activity in laboratory and diagnostic applications.

Hydrogels are intensively investigated biomaterials due to their useful physicochemical and biological properties in bioengineering. In particular, naturally occurring hydrogels are being deployed as carriers for bio-compounds. We used two approaches to develop a plate colourimetric test by immobilising (1) ABTS or (2) laccase from Trametes versicolor in the gelatine-based hydrogel. The first system (1) was applied to detect laccase in aqueous samples. We investigated the detection level of the enzyme between 0.05 and 100 µg/mL and pH ranging between 3 and 9; the stability of ABTS in the solution and the immobilised form, as well as the retention functional property of the hydrogel in 4 °C for 30 days. The test can detect laccase within 20 min in the concentration range of 2.5−100 µg/mL; is effective at pH 3−6; preserves high stability and functionality under storage and can be also successfully applied for testing samples from a microbial culture. The second system with the immobilised laccase (2) was tested in terms of substrate specificity (ABTS, syringaldazine, guaiacol) and inhibitor (NaN3) screening. ABTS appeared the most proper substrate for laccase with detection sensitivity CABTS > 0.5 mg/mL. The NaN3 tested in the range of 0.5−100 µg/mL showed a distinct inhibition effect in 20 min for 0.5 µg/mL and total inhibition for ≥75 µg/mL.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Gold nanoparticles-anchored peptides enable precise colorimetric estimation of microplastics

Researchers developed a colorimetric method for detecting microplastics using gold nanoparticle-anchored peptides that selectively bind plastic surfaces, enabling precise and rapid estimation of microplastic contamination in aquatic environments.

Article Tier 2

A cork based substrate coupled with artificial antibodies for point-of-care detection of pro-inflammatory cytokine biomarkers

Researchers developed a cork-based point-of-care diagnostic device using artificial antibodies for rapid detection of pro-inflammatory cytokine biomarkers in biological fluids, offering a low-cost monitoring tool for inflammation.

Article Tier 2

Development of dye-staining method for microplastics detection

Researchers developed a tailored dye-staining method for detecting microplastics and microfibers, proposing a selective staining protocol designed to improve visualization and identification accuracy. The study presents this approach as a practical analytical tool for microplastic detection in environmental and laboratory samples.

Article Tier 2

An Electrochemical Biosensing Approach for Detection of Microplastic Beads

Researchers developed an electrochemical enzyme-based biosensor to detect microplastic beads across a range of sizes in water, providing a simpler and lower-cost detection approach than conventional spectroscopic methods for environmental and public health monitoring.

Article Tier 2

Identification of Pristine and Protein Corona Coated Micro- and Nanoplastic Particles with a Colorimetric Sensor Array

Scientists developed a low-cost colorimetric sensor array — essentially a panel of color-changing dyes — capable of detecting and distinguishing different types of micro- and nanoplastics at concentrations as low as 10 nanograms per milliliter. The tool can also differentiate between bare plastic particles and those coated with proteins (as would happen in a biological environment), making it a promising rapid-screening method for microplastic monitoring in water.

Share this paper