0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Gut & Microbiome Policy & Risk Remediation Sign in to save

Improvement of Clean Water Product Quality Through Desinfection Process

Journal of Scientech Research and Development 2022 Score: 35 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Munawar Ali, Dwi Sukma Donoriyanto, Nur Rahmawati

Summary

Researchers evaluated a biofilter-based water treatment system in Indonesia, finding that without disinfection the treated water contained 1,880 fecal coliforms and 2,060 total coliforms per 100 mL far exceeding environmental quality standards, and demonstrated that adding a disinfection stage reduced bacterial counts to acceptable levels.

In the process of treating raw water into clean water, the pathogenic bacteria must be eliminated. The process of eliminating pathogenic bacteria which then cause an unpleasant odor can be carried out by disinfection. The thing that needs to be considered in the context of disinfection is how to prevent the transfer of germs to the human body through clean water by breaking the chain between the two by means of disinfection. This research begins with a laboratory test of the total coliform content in water treated by Biofilter without disinfection. The laboratory test results showed that the content of Fecal Coli was 1880/100 ml and the bacteria in the Coli group were 2060/100 ml. This parameter must be reduced to the limit according to the Environmental Quality Standard (BML) using a disinfection treatment. From the observations made on the coagulation process from raw water it can be informed that in the range of observed variables, with an increase in the dose of Calcium Hypochlorite (Ca (OCl) 2) from 1 mg / lt to 3 mg / l in the disinfection process, the number of E. coli bacteria which is being lowered more and more. At a dose of Calcium Hypochlorite Ca (OCl) 2 2.5 mg in 1 liter of raw water for the Kebon Agung Canal Drainage Channel with a stirring time of 30 minutes was able to reduce the number of E. Coli bacteria by 99, 40%.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

The application of different methods for indirect microbial development assessment in pilot scale drinking water biofilters

Researchers evaluated methods for monitoring biofilm growth in biological activated carbon filters used in drinking water treatment. Different indirect measurement approaches varied in accuracy and practicality. Reliable biofilm monitoring is important for maintaining filter performance and ensuring treated water is free from microbial and chemical contaminants.

Article Tier 2

Performance of Conventional Drinking Water Treatment Plants in Removing Microplastics in East Java, Indonesia

This Indonesian study tested two conventional drinking water treatment plants in East Java for their ability to remove microplastics, finding that full multi-stage treatment achieved significant reduction but did not eliminate all particles. The results show that conventional water treatment partially protects consumers but may not prevent all microplastic ingestion through drinking water.

Article Tier 2

Comprehensive Evaluation of Advanced Water Filtration Techniques: Assessing Efficacy in Removing Hazardous Contaminants and Inhibiting Bacterial Proliferation

Researchers designed an innovative eco-friendly filtration system and compared its performance against reverse osmosis, activated carbon, and LifeStraw filters for removing nitrates, nitrites, and sulfates from water sources while assessing bacterial presence post-filtration.

Article Tier 2

Microplastic Contamination in Drinking Water Treatment Systems: A Case Study of Bedadung River Jember

Researchers traced microplastic contamination through the Bedadung River water treatment chain in Indonesia, from intake to consumer taps, at seven sampling points. MPs were present throughout the system, with concentrations declining through treatment stages but not reaching zero, indicating residual MP exposure in treated drinking water.

Article Tier 2

Comprehensive Evaluation of Advanced Water Filtration Techniques: Assessing Efficacy in Removing Hazardous Contaminants and Inhibiting Bacterial Proliferation Translational Medical Science

Researchers designed an innovative eco-friendly filtration system and evaluated its performance against reverse osmosis, activated carbon, and LifeStraw filters for removing nitrates, nitrites, and sulfates from water while monitoring bacterial levels post-filtration.

Share this paper