0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Remediation Sign in to save

The suitability and mechanism of polyaluminum-titanium chloride composite coagulant (PATC) for polystyrene microplastic removal: Structural characterization and theoretical calculation

Water Research 2023 74 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 65 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Beibei Liu, Yue Gao, Qinyan Yue, Kangying Guo, Baoyu Gao

Summary

Researchers developed a new coagulant (a chemical that clumps particles together for removal) that effectively removes polystyrene microplastics from water. The composite coagulant worked better than standard water treatment chemicals across a wider range of water conditions, using hydrogen bonding to capture the plastic particles. This technology could improve drinking water treatment plants' ability to filter out microplastics before water reaches consumers.

Polymers

Microplastics (MPs) particles bring potential threats to the aqueous environment, and the coexistence of natural organic matter (NOM) enhances their toxicity. Coagulation is an efficient method for particle removal and exploring the binding sites and modes of the coagulant hydrolysates with MPs in the presence of NOM is essential to understand the coagulation mechanism. In this study, a novel polymerized polyaluminum-titanium chloride composite coagulant (PATC) was prepared and used to remove polystyrene (PS). It was found that PATC could compress or even destroy the surface layer of the negatively charged PS. In comparison to PAC and PTC, PATC was more efficient in decreasing the energy barrier of the PS particles and increasing their aggregation rate over a wider pH range. The results of the Extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) calculation revealed that the interaction between the hydrolysates of PATC and PS was mainly polar interaction (V), such as hydrogen bonding. The peak intensity and peak shift in Fourier-transformed infrared (FTIR) and X-ray photoelectron spectra (XPS) were analyzed to further explore the interaction between the hydrolysates of PATC and PS. It was found that hydrogen bonding existed between the -OH group of PATC and the aliphatic C-H and C=O groups of PS. And the main interaction between HA and PS was the π-π* conjugation and hydrogen bonding between the -COOH, -OH, and C=O groups of HA and the C=O and aliphatic C-H groups of PS. Therefore, in the HA@PS system, the active sites of HA (e.g. -COOH and -OH) and PS (e.g., C=O and aliphatic C-H) binding with the coagulants were occupied, which accordingly led to the dramatic decline in the removal efficiency of both HA and PS. In actual lake water treatment, although the removal efficiency of PS was significantly poor, PATC performed better for PS removal than PAC and PTC. Besides, the effluent pH was maintained at 6.81±0.08, which met the requirements of the subsequent water treatment process. This study provides systematic knowledge for understanding the interaction between PS, NOM, and coagulant hydrolysates, and further confirms the application potential of PATC for MPs removal.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

New insights into the fate and interaction mechanisms of hydrolyzed aluminum-titanium species in the removal of aged polystyrene

Researchers investigated the interaction between polyaluminum-titanium chloride composite coagulant species and aged polystyrene microplastics, revealing how species transformation during coagulation affects the removal efficiency of microplastics from water.

Article Tier 2

Microcosmic mechanism analysis of the combined pollution of aged polystyrene with humic acid and its efficient removal by a composite coagulant

Researchers analyzed how aged polystyrene interacts with humic acid at the molecular level and developed a novel polyaluminum-titanium chloride composite coagulant that effectively removes these combined pollutants from water across different pH conditions.

Article Tier 2

Uncovering the performance and intrinsic mechanism of different hydrolyzed AlTi species in polystyrene nanoplastics coagulation

Researchers systematically compared how different aluminum-titanium coagulant species remove nanoplastics from water, finding that polymeric AlTi species outperform monomeric ones by achieving 95% turbidity removal at lower doses through a combination of charge neutralization and chemical complexation with the nanoplastic surface.

Article Tier 2

Effect of Microplastics on the Coagulation Mechanism of Polyaluminum–Titanium Chloride Composite Coagulant for Organic Matter Removal Revealed by Optical Spectroscopy

This study investigated how microplastics interfere with a water treatment coagulant (PATC) designed to remove dissolved organic matter from drinking water. High concentrations of aged polystyrene microplastics competed with organic matter for active binding sites on the coagulant, reducing its effectiveness at removing certain compounds while also slowing the breakdown of its most reactive component. The results show microplastics in source water can compromise the efficiency of conventional water purification processes.

Article Tier 2

Improving nanoplastic removal by coagulation: Impact mechanism of particle size and water chemical conditions

Researchers found that coagulation using aluminum chlorohydrate and polyacrylamide achieved up to 98.5% removal efficiency for polystyrene nanoplastics, with smaller particles being easier to remove, though humic acid in water competed for adsorption sites and reduced effectiveness.

Share this paper