We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Quantitative Detection of Natural Rubber Content in Eucommia ulmoides by Portable Pyrolysis-Membrane Inlet Mass Spectrometry
Summary
Researchers developed a portable pyrolysis-membrane inlet mass spectrometry (PY-MIMS) method for the rapid and quantitative detection of natural rubber content in Eucommia ulmoides, offering a fast analytical tool for quality control in rubber and biopolymer applications.
Eucommia ulmoides gum (EUG) is a natural polymer predominantly consisting of trans-1,4-polyisoprene. Due to its excellent crystallization efficiency and rubber-plastic duality, EUG finds applications in various fields, including medical equipment, national defense, and civil industry. Here, we devised a portable pyrolysis-membrane inlet mass spectrometry (PY-MIMS) approach to rapidly, accurately, and quantitatively identify rubber content in Eucommia ulmoides (EU). EUG is first introduced into the pyrolyzer and pyrolyzed into tiny molecules, which are then dissolved and diffusively transported via the polydimethylsiloxane (PDMS) membrane before entering the quadrupole mass spectrometer for quantitative analysis. The results indicate that the limit of detection (LOD) for EUG is 1.36 μg/mg, and the recovery rate ranges from 95.04% to 104.96%. Compared to the result of pyrolysis-gas chromatography (PY-GC), the average relative error is 1.153%, and the detection time was reduced to less than 5 min, demonstrating that the procedure was reliable, accurate, and efficient. The method has the potential to be employed to precisely identify the rubber content of natural rubber-producing plants such as Eucommia ulmoides, Taraxacum kok-saghyz (TKS), Guayule, and Thorn lettuce.
Sign in to start a discussion.
More Papers Like This
Rapid Determination of Taraxacum kok-saghyz Rubber Content Using a Pyrolyzer Hyphenated with a Miniaturized Mass Spectrometer
Researchers developed a pyrolysis-mass spectrometry (PY-MS) instrument for rapid quantification of natural rubber content in Taraxacum kok-saghyz, a promising alternative rubber-producing plant, achieving a correlation coefficient above 0.99, recovery rates of 93.27-107.83%, and analysis times of just 10 minutes per sample. The portable system design enables on-site, in situ analysis to support TKS breeding programs and has potential application for assessing rubber content in other high-molecular-weight polymer-producing plants.
Rapid Determination of Taraxacum kok-saghyz Rubber Content by Pyrolyzer Hyphenated with a Miniaturized Mass Spectrometer
Not relevant to microplastics — this paper develops a pyrolysis-mass spectrometry method to rapidly quantify natural rubber content in the dandelion species Taraxacum kok-saghyz, a candidate alternative to rubber trees.
Determination of Tire Wear Particle-Type Polymers by Combination of Quantitative Nuclear Magnetic Resonance Spectroscopy and Soxhlet Extraction
Researchers combined quantitative pyrolysis-GC/MS with other analytical methods to specifically identify and quantify tire wear particle-derived polymers in environmental samples. The approach enables more accurate attribution of rubber polymer contamination to tire wear versus other sources.
Determination of Tire Wear Particle-Type Polymers by Combination of Quantitative Nuclear Magnetic Resonance Spectroscopy and Soxhlet Extraction
Researchers developed a method combining quantitative NMR spectroscopy with Soxhlet extraction to identify and quantify tire wear particle polymers including natural rubber, styrene-butadiene copolymer, ethylene-propylene copolymer, and polybutadiene. Limits of quantification ranged from 3 to 43 µg per sample with recovery rates of 72-92%, offering an alternative to IR and Raman spectroscopy which are impaired by tire additives and fillers.
Rapid Monitoring Approach for Microplastics Using Portable Pyrolysis-Mass Spectrometry
Researchers developed a rapid monitoring method for microplastics using a portable pyrolysis-mass spectrometry system that can identify polymer types and quantify particles smaller than 5 mm in the field without lengthy laboratory preparation. The approach offers a promising tool for fast, on-site microplastic surveillance in environmental samples.