0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Remediation Sign in to save

Composite Polysilicate Metal Coagulants for Simultaneous Removal of Organic Matter, Phosphorus, and Ammonium-Nitrogen: Effects of Metal/Silicate Molar Ratio and Basicity

Water 2023 5 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 35 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Hanxu Guo, Peng Li, Lianfeng Du, Lianfeng Du, Guoyuan Zou, Xuan Guo

Summary

Researchers prepared composite polysilicate metal (CSM) flocculants combining Fe3+ and Mg2+ ions in polysilicic acid and evaluated their performance for simultaneously removing organic matter, phosphorus, and ammonium-nitrogen from wastewater, finding that metal-to-silicate molar ratio and basicity significantly affect removal efficiency.

Study Type Environmental

Coagulation can effectively recover substances from wastewater; however, there is a lack of efficient coagulants for simultaneous recovery of organic matter, nitrogen, and phosphorus. We prepared a composite polysilicate metal (CSM) flocculant by combining Fe3+ and Mg2+ ions in polysilicic acid (PSiA). According to the results of scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR), the CSM exhibited a larger amorphous phase along with new compounds, including Mg3Fe2(SiO4)3 and hydroxyl metals. The CSM demonstrated a higher coagulation efficiency than PSiA and polymeric ferric sulfate, particularly for PO43−-P and NH4+-N removal. The metal/silicate molar ratio substantially influenced the structure and composition of the CSM, along with the coagulation efficiency, with an optimal ratio of 3:1. Additionally, we proposed a novel preparation strategy to achieve an optimum CSM basicity (B*) for coagulation by adjusting the initial pH of PSiA (pHInitial) without adding an alkali agent. The results demonstrated that the optimum B* can be obtained by adjusting pHInitial to 0.5 or 1. The overall optimum coagulation performance for the simultaneous removal of organic matter, PO43−P, and NH4+-N from wastewater was 68.5%, 99%, and 17.5%, respectively. This study provides a feasible approach for synchronous pollutant recovery from wastewater.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Microcosmic mechanism analysis of the combined pollution of aged polystyrene with humic acid and its efficient removal by a composite coagulant

Researchers analyzed how aged polystyrene interacts with humic acid at the molecular level and developed a novel polyaluminum-titanium chloride composite coagulant that effectively removes these combined pollutants from water across different pH conditions.

Article Tier 2

Efficient Removal of Polyethylene UsingMagnesium Hydroxide and AnionicPolyacrylamide as Dual-Coagulant byCoagulation-Flocculation Processes

Researchers investigated the removal of polyethylene microplastics from simulated natural water using magnesium hydroxide and anionic polyacrylamide as dual coagulants, finding optimal conditions at 40 mg/L Mg2+, pH 12, and 20°C, achieving high removal efficiency via coagulation-flocculation.

Article Tier 2

Preparation and Application of Si@Al Adsorbents for Different Pollutants Removal from Aqueous Solution

Researchers prepared a low-cost Si@Al adsorbent from electroflocculation waste by mixing sodium silicate at a 4:1 ratio and calcining at 200 degrees Celsius, demonstrating its efficient removal of organic pollutants, antibiotics, and metal ions from aqueous solutions.

Article Tier 2

Coagulation–Sedimentation in Water and Wastewater Treatment: Removal of Pesticides, Pharmaceuticals, PFAS, Microplastics, and Natural Organic Matter

This review evaluated how coagulation-sedimentation processes in water and wastewater treatment perform against emerging contaminants including microplastics, pharmaceuticals, pesticides, and PFAS. Researchers found that conventional coagulants can remove up to 95% of micro- and nanoplastics but are less effective for pharmaceuticals and PFAS, and that novel coagulant systems and hybrid approaches show promise for improving removal across contaminant types.

Article Tier 2

Investigating the Potential of Coagulants to Improve Microplastics Removal in Wastewater and Tap Water

Researchers found that adding coagulants (FeCl3 or Al2(SO4)3) to wastewater and tap water improved microplastic removal, with aluminum sulfate achieving 43% and 62% removal efficiencies respectively, though the high concentrations required suggest that combining coagulants with organic polyelectrolytes could improve practicality.

Share this paper