0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Sign in to save

Simplified 3D hydrodynamic flow focusing for lab-on-chip single particle study

Scientific Reports 2023 17 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 45 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Filippo Storti, Silvio Bonfadini, Luigino Criante

Summary

Researchers developed a compact microfluidic device carved into glass using lasers that can precisely align particles in three dimensions for single-particle analysis in flowing liquid. The chip successfully focused particles as small as 1 micrometer and was tested for detecting bacteria in water, with potential applications in analyzing microplastics and biological particles.

Accurately control of the position of a fluid and particle within lab-on-a-chip platform is a critical prerequisite for many downstream analysis processes, such as detection, trapping and separation, moving the sensing at the single-particle level. With the development of microfluidic fabrication technology, particle/cell focusing has shifted from two to three dimensions. 3D hydrodynamic focusing, which sorts and aligns the incoming cloud of particles so that they pass through the interrogation area one by one, enables new possibilities and breakthroughs in the single-cell analysis system. Despite the excellent results shown in literature, there is still a lack of a device that can simultaneously fulfilling the requirements of high throughput, compactness, high integrability, and ease of use operation to become a widely accepted work center for biomedical research and clinical applications. Here, we proposed a unique 3D flow focusing microfluidic device buried in fused silica substrate that potentially combines all this advantages. By designing a sample channel suspended inside a larger buffer channel, manufactured by exploiting the laser-assisted micromachine technique, a not size-dependent focusing capability is shown. A spatially and temporally stable central flow of a mixture of 15 μm and 6 μm PS particles to a 1 μm PS microsphere solution has been obtained with high accuracy. Finally, to test the achievable focusing resolution, the chip was tested for the detection of Escherichia Coli bacteria in water solution as proof of concept of biological application.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Microfluidics and Chip Development

Researchers developed microfluidic lab-on-chip approaches for two applications: bacterial analysis and microplastic separation, using the principles of fluid dynamics at small scales to create controlled testing conditions within compact chip environments. The project demonstrated that microfluidic platforms can be adapted for environmental monitoring of microplastics, offering a miniaturised and potentially high-throughput detection alternative to conventional methods.

Article Tier 2

An opto-acousto-fluidic microchip for efficient Raman spectroscopy of microparticles in aqueous environment

Researchers developed a novel microchip that combines microfluidics with acoustic trapping and Raman spectroscopy to analyze microparticles in water. The device uses sound waves to hold particles in place while laser-based chemical analysis identifies their composition in real time. The technology could improve the speed and accuracy of detecting microplastics in environmental water samples.

Article Tier 2

Application of a Micro Free-Flow Electrophoresis 3D Printed Lab-on-a-Chip for Micro-Nanoparticles Analysis

Researchers developed a 3D-printed microfluidic chip using free-flow electrophoresis to separate and analyze micro- and nanoparticles in a low-cost, reproducible device. This type of miniaturized lab technology could improve environmental monitoring of nanoplastics and other fine particles in water samples.

Article Tier 2

Sheathless Elasto‐Inertial Focusing of Sub‐25 Nm Particles in Straight Microchannels

Scientists developed a new method to focus and separate nanoparticles as small as 25 nanometers using microchannels and special fluid properties, without needing any external equipment like electric fields. They successfully focused biological particles including lipoproteins and extracellular vesicles, which are important for medical diagnostics. While the technology was designed for biomedical applications, it could also be applied to detecting and separating nanoplastics from environmental samples.

Article Tier 2

Review: Impact of microfluidic cell and particle separation techniques on microplastic removal strategies

Researchers reviewed how microfluidic technology — the same miniaturized tools used in medical diagnostics to sort cells — could be adapted to separate and recover microplastics from water, offering a more precise and scalable alternative to conventional filtration methods used in wastewater treatment.

Share this paper