Integrated Passive Sensing Chip for Highly Sensitive and Reusable Detection of Differential-Charged Nanoplastics Concentration
AI summary Read the abstract
Researchers developed a passive sensing chip based on complementary split ring resonators to detect nanoplastics of different surface charges and sizes in aqueous solution using microwave signals. The method achieved high sensitivity for positively charged nanoplastics and offers a reusable detection approach.
In this work, a new type, highly sensitive, and reusable nanoplastics (NPs) microwave detection method is proposed, which can be used to rapidly analyze NPs with different surface charges and sizes. The effective dielectric constant of NPs varies according to the different concentrations, particle sizes, and surface charges of NPs in aqueous solution. The feasibility of the microwave method for differential-charged NPs detection is verified using a complementary split ring resonator sensor manufactured on a cost-effective printed circuit board, which shows a high sensitivity only for positively charged NPs (PS-NH2) detection. To achieve microwave detection of both positively and negatively charged NPs (PS-SO3H), a microscale spiral-coupled resonator sensing chip is manufactured through integrated passive technology, which demonstrates extremely low detection limits and high sensitivity for both PS-NH2 and PS-SO3H, with different concentrations, particle sizes, and charges. In addition, for NPs solution doped with methyl orange, the device can still perform stable measurements, overcoming the inability of traditional NPs molecular element determination and optical detection methods to detect NPs aqueous solution with organic matter doping and color presence. The proposed microwave detection method could also be extended to sensing detection for detecting other hazardous environmental substances.
More Papers Like This
SRR-Based Disposable Microwave-Microfluidic Sensor for Assessing Liquid Carrier Influence on Microplastic Detection
AI summary Read the abstract
Researchers developed a double split-ring resonator microwave-microfluidic sensor that can detect polyethylene microplastics in various liquid carriers (including agricultural water with dissolved salts), minimizing the effect of liquid composition on detection accuracy.
Size and concentration characterization of microplastic particles in aqueous samples using sensitivity-enhanced coupled planar microwave resonators
AI summary Read the abstract
Researchers developed a novel microwave sensing platform for real-time detection and characterization of microplastic particles in water samples. The sensor uses an enhanced coupled planar microwave resonator design with a low-cost disposable sample holder, enabling rapid, non-destructive measurement of microplastic particle size and concentration without cross-contamination between tests.
Passive Disposable Microwave Sensor for Online Microplastic Contamination Monitoring
AI summary Read the abstract
Researchers developed a passive disposable microwave sensor for online monitoring of microplastic contamination in water, using a sensitivity-enhanced planar dual-resonator tag-reader structure combined with a silicon resonator to enable non-contact concentration measurement.
Detection of microplastics by microfluidic microwave sensing: An exploratory study
AI summary Read the abstract
Researchers developed a compact microwave sensor on a microfluidic chip to detect microplastics in water samples. The system works by measuring how the presence of plastic particles changes the electrical properties of water. While the technology shows promise as a rapid and portable detection method, its current sensitivity needs improvement before it can detect the low microplastic concentrations typically found in natural freshwater.
Microplastic Detection Using Dual-Mode Complementary Split-Ring Resonator
AI summary Read the abstract
Researchers developed a microplastic detection sensor using dual-mode complementary split-ring resonators operating at 2.45 and 5.8 GHz ISM bands, achieving concentration measurements of polyethylene in water with errors under 3.51% across 0–800 ppm ranges. Accurate, low-cost sensing technology like this is essential for real-time environmental monitoring of microplastic levels in water systems before they reach drinking water supplies.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.