0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Remediation Sign in to save

Synthesis and Characterization of PVA-Enzyme/GA/PANI-HCl Indicator Membrane Electrodes; PANI-p-toluentsulfonic acid/PVC-KTpClPB-o-NPOE, SEM-EDX, XRD and FTIR Analysis

Jurnal Penelitian Pendidikan IPA 2023 Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Abd Hakim S, Martha Rianna, Jane Elnovreny

Summary

This electrochemistry paper describes the fabrication and characterization of composite polymer membrane electrodes for analytical detection. The study is focused on sensor development and is not directly related to microplastic environmental research.

Polymers

Research has been carried out on the indicator electrode PVA-Enzyme/GA-2.9%/PPy+Sulfonic Acid/PVC-KTpClPB-o-NPOE, the amorphous spectral pattern is greatly reduced for variations of the enzyme 0.6 g in 0.5 mL (50% water + 50% alcohol) . PVA-Enzyme/GA-2.9%/PPy+Sulfonic Acid/PVC-KTpClPB-o-NPOE indicator electrode, denoted As-1. Analysis of the linear curve of the As-1 sample with a sensitivity of 41.56 mV/decade, a detection range of 10-4 - 10-1 M and a detection limit of 10-4 M, R2 = 97.51 %. To increase the sensitivity, detection range, detection limit and confidence level of R2. Indicator electrodes were made with variations of the urease enzyme on PVA and o-NPOE variations on PVC-KTpClPB 61% and 66% and replacement of PANI conductive polymer. PANI conductive polymer was dissolved in hydrochloric acid HCl denoted PANI-HCl and p-toluensulfonic acid is denoted by PANI-p-toluensulfonic acid. SEM analysis shows that the morphology of S3 is greater than that of S2. Analysis of the cps/eV EDX voltage range is greater than S3 to S2. Analysis of the XRD intensity spectrum pattern on the 2theta diffraction angle is greater than S3 to S2. Likewise, the analysis of the %Transmittance FTIR spectrum pattern for wave numbers S3, S6, S8 is higher than S2. The best result according to material analysis is S3.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Design, fabrication, and application of electrochemical sensors for microplastic detection: a state-of-the-art review and future perspectives

This review covers recent advances in electrochemical sensors for detecting microplastics in environmental samples, which offer advantages in sensitivity and portability over conventional laboratory methods. Researchers highlight strategies using nanomaterials, molecular imprinting, and surface-enhanced techniques to improve detection capabilities. The study suggests that electrochemical sensors represent a promising path toward affordable, rapid, on-site monitoring of microplastic pollution.

Article Tier 2

Current perspectives, challenges, and future directions in the electrochemical detection of microplastics

This review examines the emerging use of electrochemical sensors for detecting microplastics in the environment. Researchers found that while electrochemical methods have been widely explored for microplastic removal, their potential as low-cost detection tools remains largely untapped. The study highlights recent advances in nanoimpact techniques and electrode modifications that could make environmental microplastic monitoring more practical and affordable.

Article Tier 2

Electrochemical approaches for detecting micro and nano-plastics in different environmental matrices

This review evaluates electrochemical sensor technologies as alternatives to conventional spectroscopy methods for detecting micro- and nanoplastics in environmental samples. Researchers found that electrochemical approaches offer advantages in cost, portability, and speed, making them better suited for widespread field monitoring. The study identifies key technical challenges that need to be resolved before these sensors can be broadly adopted for routine environmental surveillance.

Article Tier 2

Electrochemical and Surface‐Enhanced Raman Scattering Coupling for Dual‐Mode Sensing of Nanoplastics

This study developed a dual-mode detection system combining electrochemical analysis with surface-enhanced Raman scattering to identify nanoplastics in environmental samples, addressing the challenge of detecting NPs by material, size, and surface chemistry simultaneously.

Article Tier 2

Nanomaterial-based electrochemical chemo(bio)sensors for the detection of nanoplastic residues: trends and future prospects

This study reviews how nanomaterial-based electrochemical sensors can be used to detect tiny nanoplastic residues in water. Researchers found that these sensors offer a promising, practical approach for monitoring nanoplastic contamination in aquatic ecosystems. The findings suggest that advancing these detection tools is important for implementing effective water quality control measures.

Share this paper