In Situ Formation of a Relatively Transparent Ion-Associate Liquid Phase from an Aqueous Phase and Its Application to Microextraction/High-Performance Liquid Chromatography–Fluorescence Detection of Bisphenol A in Water
AI summary Read the abstract
Researchers developed a simple microextraction method for detecting bisphenol A (BPA) in water by forming an in situ ion-associate liquid phase using ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate, followed by HPLC with fluorescence or electrochemical detection, achieving detection limits as low as 0.009 µg/L.
The design of a simple approach enabling the detection of bisphenol A (BPA) in water samples without the need for large amounts of solvents is of utmost importance. This paper reports a simple method for the separation, concentration, and quantification of BPA in water samples using high-performance liquid chromatography with fluorescence detection (HPLC-FLD) after its microextraction into an in situ formed organic ion-associate (IA) liquid phase (LP). Novel IA phase components without conjugated double bonds, such as benzene rings, were investigated. Ethylhexyloxypropylamine hydrochloride and sodium dodecyl sulfate solutions were added to the water samples to form IAs. The aqueous phase and ion-associate liquid phase (IALP) were separated by centrifugation. The aqueous phase was removed, and the liquid phase was recovered and measured using HPLC-FLD or HPLC-electrochemical detection (ECD). The concentrated phase (IALP) had a relatively low viscosity and could be injected directly into the chromatograph without dissolving it in organic solvents. The detection limits for BPA by HPLC-FLD and HPLC-ECD were 0.009 and 0.3 µg L-1, respectively.
More Papers Like This
Embedded Optical Sensor System for Bisphenol A Detection
AI summary Read the abstract
Researchers developed a portable optical sensor system for detecting both microplastics and bisphenol A (BPA) in water using spectroscopy and fluorescence principles. Early testing showed the sensor can detect BPA at nanomolar concentrations and identify microplastics as small as a few micrometers, with results comparable to established laboratory methods like HPLC and FTIR spectroscopy.
Embedded Optical Sensor System for Bisphenol A Detection
AI summary Read the abstract
Researchers developed a portable optical sensor system for detecting both microplastics and bisphenol A (BPA) in water using spectroscopy and fluorescence principles. Early testing showed the sensor can detect BPA at nanomolar concentrations and identify microplastics as small as a few micrometers, with results comparable to established laboratory methods like HPLC and FTIR spectroscopy.
Monitoring Poly(methyl methacrylate) and Polyvinyl Dichloride Micro/Nanoplastics in Water by Direct Solid-Phase Microextraction Coupled to Gas Chromatography–Mass Spectrometry
AI summary Read the abstract
Researchers developed a novel method for detecting and quantifying micro- and nanoplastics in water using solid-phase microextraction coupled with gas chromatography-mass spectrometry. The technique successfully identified poly(methyl methacrylate) and polyvinyl dichloride particles at low concentrations without requiring extensive sample preparation. The study offers a simpler, more sustainable, and more sensitive approach for monitoring plastic particle contamination in aqueous environments.
Graphene and gold nanoparticle-based bionanocomposite for the voltammetric determination of bisphenol A in (micro)plastics
AI summary Read the abstract
Researchers developed a highly sensitive electrochemical sensor using graphene and gold nanoparticles to detect bisphenol A leaching from plastics and microplastics in water. The sensor achieved very low detection limits and worked reliably in real water samples. This tool could help environmental scientists and regulators better monitor harmful chemical release from plastic pollution in freshwater and marine environments.
Fast and portable fluorescence lifetime analysis for early warning detection of micro- and nanoplastics in water
AI summary Read the abstract
Researchers developed a portable fluorescence-based system that can detect micro- and nanoplastics in water without any sample preparation or labeling. The method works by measuring the natural fluorescence lifetime of plastic particles using a pulsed laser, achieving detection limits as low as 0.01 mg/mL. The study presents a promising early-warning tool for rapid, on-site monitoring of plastic contamination in water sources.