0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Food & Water Policy & Risk Sign in to save

Optimization of Electrolytes with Redox Reagents to Improve the Impedimetric Signal for Use with a Low-Cost Analyzer

Biosensors 2023 5 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 35 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Yu‐Hsuan Cheng, Charmi Chande, Zhenglong Li, Niranjan Haridas Menon, Sreerag Kaaliveetil, Sagnik Basuray

Summary

Researchers investigated the optimization of electrolytes with redox reagents to improve impedimetric signal quality for use with low-cost point-of-care analyzers. The study identified electrolyte formulations that enhance sensitivity and signal-to-noise ratio, providing a pathway for transitioning affordable electrochemical sensing systems toward meeting ASSURED criteria.

The most well-known criterion for POC devices is ASSURED, and affordability, i.e., using low-cost instrumentation, is the most challenging one. This manuscript provides a pathway for transitioning ESSENCE, an impedance-based biosensor platform, from using an expensive benchtop analyzer-KeySight 4294A (~$50k)-to using a significantly portable and cheaper USB oscilloscope-Analog Discovery 2 (~$200) -with similar sensitivity (around 100 times price difference). To achieve this, we carried out a fundamental study of the interplay between an electrolyte like potassium chloride (KCl), and an electrolyte buffer like phosphate buffered saline (PBS) in the presence and absence of a redox buffer like ferro/ferricyanide system and ([Ru(bpy)3]2+). Redox molecules in the electrolyte caused a significant change in the Nyquist curve of the impedance depending on the redox molecule type. The redox species and the background electrolyte have their own RC semicircles in the Nyquist curve, whose overlap depends on the redox concentration and electrolyte ionic strength. We found that by increasing the electrolyte ionic strength or the redox concentration, the RC semicircle moves to higher frequencies and vice versa. Importantly, the use of the buffer electrolyte, instead of KCl, led to a lower standard deviation and overall signal (lesser sensitivity). However, to achieve the best results from the biorecognition signal, we chose a buffered electrolyte like PBS with high ionic strength and lowered the redox probe concentrations to minimize the standard deviation and reduce any noise from migrating to the low-cost analyzer. Comparing the two analyzers shows similar results, with a lowered detection limit from the low-cost analyzer.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Electrochemical Sensors and Biosensors for Food, Environmental and Biomedical Analysis

Researchers reviewed the field of electrochemical sensors and biosensors, evaluating their sensitivity and selectivity for applications in food safety, environmental monitoring, and biomedical diagnostics as miniaturized alternatives to conventional analytical gold standards.

Article Tier 2

Portable potentiometric device for determining the antioxidant capacity

This paper describes the development of a portable electrochemical device for rapidly measuring antioxidant capacity in biological and environmental samples, offering a simpler alternative to laboratory-based methods.

Article Tier 2

Electrochemical Sensor for Antibiotic Detection

This review examines the design principles, transduction mechanisms, and performance characteristics of electrochemical biosensors for antibiotic detection, covering enzyme-based, aptamer-based, and molecularly imprinted polymer approaches and highlighting the integration of nanomaterials and microfluidics to address the challenge of antibiotic resistance monitoring.

Article Tier 2

Integrated Electrochemical Biosensors for Detection of Waterborne Pathogens in Low-Resource Settings

This review covers the development of electrochemical biosensors integrated with microfluidic components for detecting waterborne pathogens, highlighting their potential for portable, affordable water quality monitoring in developing countries. The authors discuss how these devices could address critical gaps in current water safety infrastructure in low-resource settings.

Article Tier 2

Design, fabrication, and application of electrochemical sensors for microplastic detection: a state-of-the-art review and future perspectives

This review covers recent advances in electrochemical sensors for detecting microplastics in environmental samples, which offer advantages in sensitivity and portability over conventional laboratory methods. Researchers highlight strategies using nanomaterials, molecular imprinting, and surface-enhanced techniques to improve detection capabilities. The study suggests that electrochemical sensors represent a promising path toward affordable, rapid, on-site monitoring of microplastic pollution.

Share this paper